Scanner Symbology Configuration Tags
Parameter Name
IBrowse_Code39_Format_FullAscii
IBrowse_Code39_StartStop_Xmit
IBrowse_Code39_StartStop_Chars
IBrowse_Code39_CheckDigit
IBrowse_Code39_Length
IBrowse_Codabar_StartStop
IBrowse_Codabar_CLSI
IBrowse_Codabar_CheckDigit
IBrowse_Codabar_Length
IBrowse_Code93_Length
IBrowse_Code128_Include_EAN128_Identifier
IBrowse_Code128_CIP128_Active
IBrowse_Code128_FNC1_Separator
IBrowse_Code128_Length
IBrowse_I2of5_CheckDigit
IBrowse_I2of5_Length
IBrowse_PDF417_Buffer_Macro
IBrowse_PDF417_Xmit_CtrlHeader
52
enabled by default. See the next page for enabling or disabling the UPCA,
UPCE, EAN8 and EAN13 symbologies.
Example
<HTML>
<HEAD>
<META HTTP-Equiv="IBrowse_I2of5" Content="Enabled">
<META HTTP-Equiv="IBrowse_Code39" Content="Disabled">
<META HTTP-Equiv="IBrowse_Scanner" Content="Enabled">
</HEAD>
<BODY>
........
</BODY>
</HTML>
These tags update the scanner symbology configuration. Note that the
applicable bar code symbology is listed in each parameter name.
Syntax
HTTP-Equiv= Parameter Name
content="{parameter value}"
Parameter Value
"True" "False"
"True" "False"
"DollarSign" "Asterisk" "Both"
"Disabled" "MOD43" "MOD43_Xmit"
"French_CIP" "French_CIP_Xmit"
"Italian_CPI" "Italian_CPI_Xmit"
0, 3–50
"Disabled" "LowerABCD"
"UpperABCD" "LowerABCDTN"
"DC1toDC4"
"True" "False"
"True" "False" "Disabled"
0, 3–50
0–50
"True" "False"
"True" "False"
ASCII value 1–127
0–50
"Disabled" "MOD10" "MOD10_Xmit"
"French_CIP" "French_CIP_Xmit"
0, 2–50
"True" "False"
"True" "False"
Default
"False" (Standard43)
"False"
"Asterisk"
"Disabled"
0
"Disabled"
"False"
"Disabled"
6
0
"True"
"False"
29
0
"Disabled"
6
"True"
"False"