Voice over PLC Sample Application
Operating Manual
Target Device
BCPX3 Evaluation Kit J80D1
All information contained in these materials, including products and product specifications,
represents information on the product at the time of publication and is subject to change by
Renesas Electronics Corp. without notice. Please review the latest information published by
Renesas Electronics Corp. through various means, including the Renesas Electronics Corp.
website (http://www.renesas.com).
www.renesas.com
Rev.2.00 June 25, 2018

Advertisement

Table of Contents
loading

Summary of Contents for Renesas J80D1

  • Page 1 All information contained in these materials, including products and product specifications, represents information on the product at the time of publication and is subject to change by Renesas Electronics Corp. without notice. Please review the latest information published by Renesas Electronics Corp. through various means, including the Renesas Electronics Corp.
  • Page 3 The following usage notes are applicable to all Microprocessing unit and Microcontroller unit products from Renesas. For detailed usage notes on the products covered by this document, refer to the relevant sections of the document as well as any technical updates that have been issued for the products.
  • Page 4: Table Of Contents

    Table of Contents Overview ........................1 Setup ..........................2 System configuration ..........................2 Hardware setting ............................2 Terminal software setting ........................... 2 Operating procedure ..................... 3 Startup screen ............................3 Main menu ..............................3 Call menu ..............................3 3.3.1 Simplex ............................. 3 3.3.2 Duplex ..............................
  • Page 5: Overview

    1. Overview This document is the operating manual, which is descriptive of the Voce over PLC sample application for BCPX3 Evaluation Kit J80D1. The sample application controls voice communication using the FPAC API. Refer to "Voice over PLC Software API Specification (R11UM0076EJ0200)" for detail of FPAC API.
  • Page 6: Setup

    Sample application is used by connecting J80D1 board and PC with USB Cable. In order to check the sound, it is necessary to connect a microphone to CN14 of the sender audio board and a speaker to CN16 of the receiver audio board.
  • Page 7: Operating Procedure

    RENESAS CONFIDENTIAL Voice over PLC Sample Application Operating Manual 3. Operating procedure RENESAS Group CONFIDENTIAL Operating procedure When using the board for the first time, the node ID must be set according to 3.5.2 after startup. 3.1 Startup screen After power on, CPX3 will be booted automatically and startup screen and main menu will be displayed.
  • Page 8: Duplex

    Voice over PLC Sample Application Operating Manual 3. Operating procedure RENESAS Group CONFIDENTIAL User specifies the destination Node IDs in decimal. If the Node ID is one, unicast transmission is started, if the Node ID is multiple, multicast transmission is started. When specifying multiple Node IDs, the user specifies the node IDs separated by spaces.
  • Page 9: Individual Editing For Eeprom

    RENESAS CONFIDENTIAL Voice over PLC Sample Application Operating Manual 3. Operating procedure RENESAS Group CONFIDENTIAL 3.5.2 Individual editing for EEPROM 1: Extend Addr 2: Node ID 3: Bitrate 4: Sampling Rate 5: Modulation --------------------------------------------- > Menu for editing Extended Address.
  • Page 10: Displaying The Eeprom Setting Value

    RENESAS CONFIDENTIAL Voice over PLC Sample Application Operating Manual 3. Operating procedure RENESAS Group CONFIDENTIAL 3.5.3 Displaying the EEPROM setting value --------------------------------------------- Extend Addr : 0xABCDABCDABCD0000 Node ID : 000 Bitrate : 32000 Sampling Rate : 8000 Modulation : BPSK The value set in EEPROM is displayed.
  • Page 11: State Information

    RENESAS CONFIDENTIAL Voice over PLC Sample Application Operating Manual 4. State information RENESAS Group CONFIDENTIAL State information The sample application has the following states. Ready : State in which voice communication is not being performed Speaking : State in which voice sending is being performed...
  • Page 12: Speaking State

    RENESAS CONFIDENTIAL Voice over PLC Sample Application Operating Manual 4. State information RENESAS Group CONFIDENTIAL 4.2 Speaking state ----- Main Menu ( SPEAKING ) --------------- 1: Finish 2: Data Send 3: Volume --------------------------------------------- > Menu to end voice communication. Menu to send binary data.
  • Page 13: Loop Back State

    RENESAS CONFIDENTIAL Voice over PLC Sample Application Operating Manual 4. State information RENESAS Group CONFIDENTIAL 4.6 Loop back state ----- Main Menu ( LOOP BACK ) --------------- 1: Finish 2: Volume --------------------------------------------- > Menu to end voice communication. Menu to change the input and output volume.
  • Page 14 Revision History Voice over PLC Sample Application Operating Manual Rev. Date Description Page Summary 1.00 December 1, 2017 First Edition issued. 2.00 June 25, 2018 Correction of errors. Add Simplex and Duplex in Call menu. Add Modulation in Setting menu. Add 3.7 Notes.
  • Page 15 Voice over PLC Sample Application Operating Manual Publication Date: Rev.2.00 June 25, 2018 Published by: Renesas Electronics Corporation...
  • Page 17 Voice over PLC Sample Application Operating Manual R11UM0083EJ0200...