Replacement Of The; St Stage Lever Cut-Off - Zavoli GE Manual

Table of Contents

Advertisement

The main body of the regulator (Fig. 2-3 and 2-4) must be carefully cleaned with a brush (Fig. 2-
5 and 2-6) and a degreasing detergent to remove oil, grease, etc. Do not use sandblasting
machines or any other kind of abrasive tool/substance, as this may damage components which
are critical for the proper operation of the regulator.
ON THE DEVICE UNTIL IT IS COMPLETELY DRY!!!!!
Fig. 2-3
Fig. 2-5

2.1 Replacement of the 1

With a punch, apply a small amount of pressure to the cut-off valve so that it separates from its
housing (Fig. 2.1-1 / 2.1-2 and 2.1-3).
ZAVOLI s.r.l. Via Pitagora n° 400 47023 Fr. Case Castagnoli, CESENA (FC), Italy
Technical Directions
for the Overhaul of
GE – GES – GEX – GEXL
Regulators/Vaporizers
st
stage lever cut-off
Page 8 of 32
Tel. (+39) 0547/ 646409 – Telefax (+39) 0547 / 646411
Web site:
www.zavoli.com
CAREFULLY BLOW COMPRESSED AIR
Fig. 2-4
Fig. 2-6
E-mail:
zavoli@zavoli.com
DT_IS_RG-007.00-E
09/10/2009

Advertisement

Table of Contents
loading

This manual is also suitable for:

GesGexGexl

Table of Contents