3 Reassembly of the Regulator/Vaporizer

Before proceeding to reassemble the components of the regulator/vaporizer (Fig. 3-1),
please make sure that all O-Ring seats are in perfect working condition to avoid potential
leaks. Also make sure that the new O-Rings are well lubricated before they are installed!!!

3.1 Installation of the cut-off valve on the 1

With a punch, insert the cut-off valve in its operating seat (Fig. 3.1 / 3.1-1 / 3.1-2 and 3.1-3),
making sure that the central part of the cut-off does not get damaged in the process.
Fig. 3.1
ZAVOLI s.r.l. Via Pitagora n° 400 47023 Fr. Case Castagnoli, CESENA (FC), Italy
Technical Directions
for the Overhaul of
GE – GES – GEX – GEXL
Regulators/Vaporizers
Fig. 3
st
stage lever