3.11

Installation of the sensitivity register

To install the sensitivity register, grease part of the spring, as shown in Fig. 3.11 and 3.11-1. Put
the greased end of the spring into place, as shown in Fig. 3.11-2. Fig. 3.11-5 shows the correct
position of the spring.
Fig. 3.11
Fig. 3.11-2
In GEX and GEXL regulators/vaporizers, a stopper must be placed on the register spring (Fig.
3.11-3 and 3.11-4). Make sure that the stopper is placed on the sensitivity register and not on the
"dot" indicated in Fig. 3.11-2.
ZAVOLI s.r.l. Via Pitagora n° 400 47023 Fr. Case Castagnoli, CESENA (FC), Italy
Technical Directions
for the Overhaul of
GE – GES – GEX – GEXL
Regulators/Vaporizers
Page 22 of 32
Tel. (+39) 0547/ 646409 – Telefax (+39) 0547 / 646411
Web site:
www.zavoli.com
E-mail:
Fig. 3.11-1
Place the greased end of the spring on the
"dot" indicated by the arrow!!!
zavoli@zavoli.com
DT_IS_RG-007.00-E
09/10/2009