If your receiver seems to be malfunctioning, please check the
following points before sending it to a service center.
PROBLEM
No power comes ON.
• The batteries are exhausted.
• The battery polarity is reversed.
No sound comes from the
• Volume level is too low.
speaker.
• Different tone is selected with tone squelch.
Frequency cannot be set.
• The lock function is activated.
• Channel indication mode is selected.
No beeps sound.
• Beep tones are turned OFF.
Receive audio is
• The operating mode is not selected correctly.
distorted.
Desired set mode item
• The desired set mode item is in expanded set
cannot be selected.
mode.
• Some set mode items cannot be selected in
the broadcast band.
POSSIBLE CAUSE

TROUBLESHOOTING

SOLUTION
• Replace the batteries.
• Check the battery polarity.
• Push [VOL Y] to obtain a suitable level.
• Check the tone using tone scan.
• Push [FUNC] + [
LOCK] to cancel the function.
(MODE)
• Turn the channel indication mode OFF in set mode.
• Turn beep tones ON in set mode.
• Select a suitable operating mode in set mode.
• Turn the expanded set mode ON.
• Choose a band other than the broadcast band.
11