Gree GPC07AH-K3NNC3D Service Manual page 51

Table of Contents

Advertisement

Service Manual
(3) Bucket full protection H8
Whether water tray is full
No
Adjust connection
Whether malfunction
is eliminated?
Maintenance
Start up the unit
H8 is displayed
No
Check whether wires for water-level
switch are connected tightly
Replace water-level
No
switch
Yes
Discharge water by referring
Yes
to instruction manual
No
Yes
Whether malfunction
is eliminated?
Replace the main board
Yes
with the same model
End
Whether malfunction
is eliminated?
Yes
No
49

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents