Gree GPC07AH-K3NNC3D Service Manual page 44

Table of Contents

Advertisement

(2) Insert joint A of heat discharge pipe (the side with "TOP" is
upwards) into the groove until you hear a sound.(As shown in
following fig)
(3) Aim the locating pole of joint B of heat discharge pipe at the
opening of joint C; rotate it slightly to make joint B and joint C
connect tightly.
joint B
Note of Install heat discharge pipe
In order to improve cooling efficiency, the heat discharge pipe
should be as short as possible and flat without curve to ensure
smooth heat discharge.(As shown in following fig)
correct
correct
●The length of the exhaust pipe is less than 1m. It is
recommended to use it with shortest length.
●When installing, exhaust pipe should be as flat as possible.
Don't prolong the pipe or connect it with other exhaust pipe.
42
the side with "TOP" is upwards
clasp
groove
locating pole
joint C
tightened status
correct
wrong
●Correct installation is as shown in figure (When installing it on
wall, height of hall should be about 40cm-130cm from floor).
opening
●Wrong installation is shown in following figure (If the pipe is
bent too much, it would easily cause malfunction.)
B. Disassemble heat discharge pipe
(1) Remove joint B from joint C.(As shown in following fig)
joint B
joint C