Page 1
AUTO - SCANNING WITH DIGITAL CONTROL LCD COLOR MEDICAL MONITOR RadiForce EX210 / EX240W Operation Manual For future reference, record the serial number of your display monitor in the space below : Serial Number The serial number is located on the back of the monitor...
Page 3
EIZO Nanao Corporation.2010 All other trademarks are the property of their reference owners. This document is subject to change without notice. EIZO provides this information as reference only. Reference to other vendor’s products does not imply any recommendation or endorsement. Revision Control...
User’s Guide TABLE OF CONTENTS Product Description and Intended Use ............Warnings and Cautions ................Symbol Explanations ................. EU Declaration of Conformity for Medical Applications ......Safety Precaution ..................Cleaning Your Monitor ................Power Management Function..............Preset Modes....................Video Signals..................... PIP / POP / PBP function ................
EX210/EX240W 3 Product Description and Intended Use Please check the following items are present when you unpack the box, and save the packing materials in case you will need to ship or transport the monitor in future. • EX210/EX240W LCD Monitor and two video cables (1) HD15 VGA cable* (1) DVI-D cable* •...
The EIZO Nanao Corporation EX210/EX240W monitor has been tested under UL 60601-1 standard and UL listed for Medical application. EIZO Nanao Corporation reserves the right to make improvements in the product(s) described herein. Product(s), therefore, may not agree in detail to the published design or specifications.
Page 7
EX210/EX240W 5 Warnings 1. Read the operating manual thoroughly and be familiar with its contents prior to using this equipment. 2. Carefully unpack the unit and check if any damage occurred during shipment. 3. Should any solid object or liquid fall into the panel, unplug the unit and have it checked by qualified personnel before operating it any further.
Page 8
User’s Guide Cautions 1. The AC Adapter must be plugged into a Grounded power outlet. 2. Use only the proprietary EX210/EX240W power supply for the EX210/EX240W monitor. Make a proper connection by ensuring that the shrink tubing completely secures the connection between the DC power cord and the extension cord.
EX210/EX240W 7 Symbol Definitions Dangerous: High Voltage Direct Current Serial Number Top – Bottom Fragile Do not get wet Consult accompanying documents. Indicates proof of conformity to applicable European Economic Community Council directives and to harmonized standards published in the official journal of the European Communities. Authorized Representative in Europe Indicates protective earth ground.
A Declaration of Conformity has been filed for this product. A sample of this document may be found in the addendum which accompanied this manual. For a copy of the Declaration of Conformity document, please contact EIZO Nanao Corporation. and request for EX210/ EX240W DOC. Prepare for Unpack Before you unpack your monitor, prepare a suitable workspace.
EX210/EX240W 9 SAFETY PRECAUTION · Avoid placing the monitor, or any other heavy object, on the power cord to prevent fire or electrical shock from damage to the power cord. · Do not expose the monitor to rain, excessive moisture, or dust to avoid fire or shock hazard.
User’s Guide POWER MANAGEMENT FUNCTION The monitor is equipped with the power management function which automatically reduce the power consumption when not in use in three power level modes. • Stand-by Mode The monitor goes into stand-by mode when the horizontal sync signal is off for about 10 seconds.
EX210/EX240W 13 PIP / POP / PBP function The following combination options are available to you: Component Main SDI1 SDI2 C-Video S-Video / RGBs SDI1 SDI2 C-Video S-Video Component / RGBs...
User’s Guide To make your installation easier, the monitor is able to Plug and Play with your system if your system also supports DDC protocol. The DDC (Display Data Channel) is a communication protocol through which the monitor automatically informs the host system about its capabilities, for example, supported resolutions and corresponding timing.
EX210/EX240W 15 CONNECTING the POWER CORD * Check first to make sure that the power cord you use is the correct type required for your area. * This monitor has an universal AC adapter that allows operation in either AC 100 - 240 V ac voltage area. No user-adjustment is required. * Plug one end of the power cord to the AC adapter, plug another end to a proper AC outlet.
User’s Guide User Functions / Messages Key Name and Function Power LED : Lights up to indicate the power is turned ON. Power Switch : To power ON or OFF the monitor. Rotary switch : With the OSD menu activated, increases the value of the selected (Ture Right) parameter or moves rightward in OSD menu.
EX210/EX240W 17 OSD Section Main Menu Chromatic Adjust Color Temp, Gamma Visual Adjust Brightness, Contrast, Phase, Chroma, Sharpness-H, Sharpness-V Setting Adjust Scale Mode, Color Space, Mirror, Freeze Frame, Zoom / Pan, PIP, POP, PBP EIZOced Adjust OSD Position Control, Screen Control, DPMS, Auto Source Select, Smart Select, Restore Factory, Key Lock Information Adjust Custom Entry, SN, Run Time, Input Format...
Page 20
User’s Guide OSD Section Chromatic Color Temp Change the color temperature - D65, D93, S1, S2 Gamma Change the gamma value - 1.8, 1.9, 1.95, 2.1, 2.1S, 2.2, 2.3, 2.4, 2.4S, S0, Radio graph Exit Exit the menu Visual Brightness Adjust the brightness of panel (Range 0 - 100) Contrast Adjust the contrast of video (Range 0 - 100)
Page 21
EX210/EX240W 19 OSD Section Setting Scale Mode Change the scale mode - Fill all, One to One, Vertical - fill, Horizontal - fill, Fill aspect ratio Color Space Change color space between RGB and YPbPr available for Component and RGBS Mirror Off / On mirror image Freeze Frame...
Page 22
User’s Guide OSD Section Sub menu of PIP Mode PIP Mode ON / Off Source PIP sub screen source - SDI1,2, C-Video, S-Video, Component, VGA, DVI, SOG Position PIP sub screen position - Top L, Top R, Bottom L, Bottom R Size PIP sub screen size - Small, Medium, Large Blending...
Page 23
EX210/EX240W 21 OSD Section Sub menu of POP Mode POP Mode ON / Off Source POP sub screen source - SDI1,2, C-Video, S-Video, Component, VGA, DVI, SOG Position POP sub screen position - Top L, Top R, Bottom L, Bottom R Size POP sub screen size - Small, Medium, Large, Full Blending...
Page 24
User’s Guide OSD Section EIZOced OSD Position Change the OSD menu - Position, Background, Control OSD time out, Language Screen Control Control and adjust H and V position, Freqency, Phase Noise Reduction, Motion Offset DPMS Change the DPMS Auto Source Adjust Auto Source Select between on and off Select Smart Select...
Page 25
EX210/EX240W 23 OSD Section Sub menu of OSD Control H-position Adjust OSD H - position (Range 0 - 100) V-position Adjust OSD V - position (Range 0 - 100) Back ground Adjust transparency of OSD back ground (Range 0 - 100) OSD Time out Adjust OSD time out - 5s, 10s, 15s, 20s, 1m, 2m Language...
Page 26
User’s Guide OSD Section Information Custom Entry Change the user or monitor’s name Display the serial number Run Time Display the total run time Input Format Display the current input resolution and vertical frequency Exit Exit the menu...
EX210/EX240W 25 TROUBLESHOOTING Before sending your LCD monitor for servicing, please check the troubleshooting list below to see if you can self-diagnose the problem. Problems Current Status Remedy No Picture LED ON · Using OSD, adjust brightness and contrast to maximum or reset to their default settings.
User’s Guide SPECIFICATION Model EX210 EX240W LCD Panel 21.3 TFT LCD Panel 24.0 TFT LCD Panel Type Active Matrix Active Martrix Resolution 1600 x 1200 @ 60Hz 1920 x 1200 @ 60Hz Pixel Pitch 0.27mm 0.27mm Display Color 16.7M colors 16.7M colors Color Tone Up to 256 color tone...
EX210/EX240W 27 : Direct Current MEDICAL EQUIPMENT WITH RESPECT TO ELECTRIC SHOCK, : UL approval mark according to the FIRE AND MECHANICAL HAZARDS ONLY safety standard for Medical equipment IN ACCORDANCE WITH UL 60601-1, AND CAN/CSA C22.2 NO. 601.1 51LJ Medical Equipment E215822 This monitor is intended for use in Health Care Facilities model EX210/EX240W...
User’s Guide Electromagnetic Compatibility Like other electrical medical equipment, the EX210/EX240W requires special precautions to ensure electromagnetic compatibility with other electrical medical devices. To ensure electromagnetic compatibility (EMC), the EX210/EX240W must be installed and operated according to the EMC information provided in this manual. Note The EX210/EX240W has been designed and tested to comply with IEC 60601-1-2:2001 requirements for EMC with other devices.
Page 31
EX210/EX240W 29 Power frequency mag- Power frequency netic fields should be (50/60Hz) mag- at levels characteristic 3.0 A/m 3.0 A/m netic field of a typical location in IEC 61000-4-8 a typical commercial or hospital environment. Mains power quaility should be that of a typical <5% Ut (>95% dip in Ut) <5% Ut (>95% dip in Ut) commercial or hospital...
Page 32
User’s Guide Recommended Separation Distances Between Portable and Mobile RF Communications Equi- pement and the EX210/EX240W System The EX210/EX240W system is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled. The user of the EX210/EX240W system can help prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF communications equipment (transmitters) and the EX210/EX240W system as recommended below, according to the maximum output power of the communications equipment.