Page 1
Instructions for Use 1MP 19" LCD Monitor Important Please read the safety information and all information delivered with the product carefully to familiarize yourself with safe and effective usage.
Use of EIZO products WARNING EIZO products may only be used for the applications described in the catalog and in the relevant tech- nical documentation. If products and components from other manufacturers are used, these must be recommended or approved by EIZO. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
Basic information on timing ............... 26 6.5.3 Entering timing data .................. 29 6.5.4 Determining the timing data .............. 30 7 Operation......................... 33 Operator controls .................... 33 Locking or unlocking the OSD menu .............. 34 Overview of the OSD menu .................. 35 CuratOR EX190 Instructions for Use, 06/2022...
Page 4
12.2 Information on electromagnetic compatibility (EMC) .......... 63 12.3 FCC Declaration of Conformity................ 68 12.4 China RoHS (Restriction of Hazardous Substances) .......... 69 12.5 Declaration of compliance with India RoHS............ 71 12.6 Environmental protection .................. 71 12.7 Warranty ......................... 71 CuratOR EX190 Instructions for Use, 06/2022...
Page 5
Table of contents 12.8 Repairs ........................ 71 12.9 Additional devices.................... 71 12.10 Contact ........................ 71 12.11 Trademarks...................... 72 Index .......................... 73 CuratOR EX190 Instructions for Use, 06/2022...
1.2 Intended use Intended purpose The CuratOR EX190 is intended for the display of still images and moving images from vari- ous commercially available devices commonly used in a medical environment, in particular radiology. The monitor is optimized for the reproduction of grayscale X-ray images. The monitor is not suitable for mammography.
2 Safety information 2.1 General safety instructions Correct and safe operation of EIZO devices assume professional transport, storage, installa- tion, and connection, as well as careful operation and service. The devices may only be used for applications for which they are intended.
Page 9
Only use power cables approved for China. These power cables are identified by the labels "CCC" or "CQC". Observe the country-specific regulations Observe all regulations of the country in which the device is used. CuratOR EX190 Instructions for Use, 06/2022...
Page 10
If the device is brought into a room with a higher or rising temperature, condensed water will form in and on the device. Do not switch on the device until the condensed water has evaporated. Other- wise, the device could be damaged. CuratOR EX190 Instructions for Use, 06/2022...
Page 11
Note that monitors can fail as a result of aging, and that image properties such as brightness, con- trast,and color value can change. Do not touch the monitor screen Due to mechanical pressure or electrostatic discharges, touching the screen can result in brief distur- bances to the image. CuratOR EX190 Instructions for Use, 06/2022...
Note Image quality To maintain constant image quality, EIZO recommends cleaning the monitor on a regular basis and checking image properties in accordance with all applicable local regulations. CuratOR EX190 Instructions for Use, 06/2022...
Keep the packaging material for subsequent transport of the device. Device The CuratOR EX190 is a 1MP 19" LCD Monitor for installation in a ceiling or wall mount, or for installation in a stand. The CuratOR EX190-S version has a stand. Otherwise, the ver- sions are identical.
Description 3.2 Features 3.2 Features The CuratOR EX190 has the following features that permit a wide range of applications: Perfect picture reproduction thanks to LCD technology The use of LCD technology eliminates picture geometry distortions and color spots. The monitor delivers flicker-free images even at low border rates (60 Hz). The monitor thus meets the strictest ergonomic requirements.
• Protect the monitor from dust, for example through appropriate construction measures at the installation site. • During transport, use the original packaging or service packaging. CuratOR EX190 Instructions for Use, 06/2022...
Mounts must be tested and approved by the manufacturer for the weight to be sup- ported. • An installed stand must be sufficiently stable to withstand tilting of up to 10° without top- pling the monitor. CuratOR EX190 Instructions for Use, 06/2022...
Device settings may only be adjusted by service personnel. NOTICE Disconnecting from line power Always set the power switch to "Off" before disconnecting the device from power. Other- wise the device could be destroyed. CuratOR EX190 Instructions for Use, 06/2022...
Page 18
• Externally connected cables can represent a trip hazard. Make sure that all incoming cables are safely routed. • If the device offers strain relief mechanisms for the cables, use them to prevent unin- tended loosening of connected cables. CuratOR EX190 Instructions for Use, 06/2022...
The connectors are located in the connection panel behind a cover on the back of the moni- tor. The power switch is not covered and is freely accessible. Fig.: Rear view with cover Fig.: Rear view without cover CuratOR EX190 Instructions for Use, 06/2022...
The device's power supply is connected using an appliance plug. Power switch The power switch is to the right next to the connection panel cover and is used to turn the device on and off. CuratOR EX190 Instructions for Use, 06/2022...
1. Using a suitable tool, remove the cover from the connection panel on the back of the de- vice. 2. Connect the appliance plug to the monitor power connector. 3. The power cable can be secured using a cable grip. 4. Place the cover back on the connection panel. CuratOR EX190 Instructions for Use, 06/2022...
3. Tighten the screws to secure the signal cables. 4. If necessary, connect the USB cable to the upstream or downstream USB ports of the monitor. 5. Place the cover back on the connection panel. CuratOR EX190 Instructions for Use, 06/2022...
"user" setting. The saved values are shown in a table in the OSD window. The predefined LUT settings saved in the monitor can be changed or updated using QA software. Note Additional information is available in the QA software instructions for use. CuratOR EX190 Instructions for Use, 06/2022...
If the horizontal position is shifted 1 pixel too far to the right for example, a 1 pixel-wide edge on the right side of the picture is lost, and a 1 pixel-wide black column is displayed on the left side. CuratOR EX190 Instructions for Use, 06/2022...
ð This is the optimum contrast value. 8. Exit the OSD to save the values. ð You have set the brightness and contrast for optimized display of the 5% and 95% squares of the SMPTE test pattern. CuratOR EX190 Instructions for Use, 06/2022...
Field 1 consists of the lines 1 to 262 1/2, and field 2 of the lines 262 1/2 to 525. Only a few lines are displayed at the top and bottom of each field. CuratOR EX190 Instructions for Use, 06/2022...
Page 27
6.5 Adapting the monitor using Force Mode Fig.: Interlaced scanning system Fig.: Non-interlaced scanning system A non-interlaced image is output to the screen such that all horizontal lines are scanned from top to bottom in a single scan. CuratOR EX190 Instructions for Use, 06/2022...
Page 28
Vertical resolution 3 - Active video (vertical resolution) Total horizontal lines 5 – Total number of lines (horizontal) Horizontal blank pixels 4 – Front Porch (horizontal) Vertical blank pixels 4 – Front Porch (vertical) CuratOR EX190 Instructions for Use, 06/2022...
5. Apply the entered data by selecting "Execute function..." Note Always save the data with "Execute function...". The timing data are only entered into memory with the "Execute function..." command, and the image is then displayed with the new parameters. CuratOR EX190 Instructions for Use, 06/2022...
Note: The timing data are only entered into memory with the "Execute function" com- mand, and the image is then displayed with the new parameters. After the "Execute function…" "Mode" switches to "Active" and you can optimize the start values. CuratOR EX190 Instructions for Use, 06/2022...
Page 31
The inactive resolution range is the unused range between the active resolution and the maximum resolution of the monitor. In Force Mode, this range is displayed gray (gray scale monitors) or blue (color monitors). Active resolution area SMPTE test pattern Inactive resolution area CuratOR EX190 Instructions for Use, 06/2022...
Page 32
Note • Only one timing can be saved in Force Mode itself. • Once all settings in Force Mode have been performed, the zoom factor can be changed in the "Geometry" menu. CuratOR EX190 Instructions for Use, 06/2022...
The four keys and the operation LED are located on the front of the monitor in the lower right corner. The operation LED illuminates when power is supplied to the device and the power switch is turned on. CuratOR EX190 Instructions for Use, 06/2022...
When the OSD is locked, the message "OSD is locked" is displayed. To lock or unlock the OSD menu, press the following keys: • Key 4 once and Key 2 three times. CuratOR EX190 Instructions for Use, 06/2022...
The menus shown in the figure can be opened from the OSD menu using the operating keys. The following sections present the menus and available settings. Note The "Adjust LUT" menu is displayed only if the "User" setting is selected in the "LUT" menu 7.4 "Image" menu CuratOR EX190 Instructions for Use, 06/2022...
Page 36
0 - 100 Set the saturation values Default: 50 Note: Saturation can be set only if the "Satu- ration in the menu Image" function in the "Sig- nal" menu is active. See also Menü "Signal" [} 40]. CuratOR EX190 Instructions for Use, 06/2022...
"Configuration auto" menu are set to the optimal value. Note: Digital image signals are always set optimally. For this reason, performing auto functions has no effect on them. Note: We recommend displaying SMPTE test patterns. CuratOR EX190 Instructions for Use, 06/2022...
Page 38
Sharpness Enhanced Select sharpness Normal When you select "Enhanced", the picture is displayed with greater sharpness. When you select "Normal", The filter set un- der "Sharpness filter" is used for the display. CuratOR EX190 Instructions for Use, 06/2022...
Page 39
If vertical lines blur easily, this can be cor- rected by adjusting the frequency. Note: To correct the frequency, we recom- mend displaying a vertical line from the "Pixel On/Off" test pattern. CuratOR EX190 Instructions for Use, 06/2022...
Note: The function is displayed only when an analog justable video source is selected. Default: Inactive and If "Active and adjustable" is selected, the "ADC Cali- hidden bration..." entry is hidden and "Saturation" is displayed in the "Image" menu. CuratOR EX190 Instructions for Use, 06/2022...
Page 41
This means that all signal information is displayed and, for example, the image is not cropped if the “Fill” value is selected for the “Image size/Zoom” function in the “Geometry” menu. CuratOR EX190 Instructions for Use, 06/2022...
When LUT "User" is selected, the LUT can be set individ- ually in the "Adapt LUT" OSD menu. See also "Adjust LUT" menu. Note: Select a DICOM LUT to view radiographic images. CuratOR EX190 Instructions for Use, 06/2022...
• Backlight operation time [h:m] • Backlight operation time over 480 cd/m • Source • Mode • Source signal • FW type • FW version • OSD version • Config version • SDK version CuratOR EX190 Instructions for Use, 06/2022...
Select the OSD menu position on the screen. Top – centered Top – right Middle – left centered Middle – right Bottom – left Bottom – centered Bottom – right Default: Top - right CuratOR EX190 Instructions for Use, 06/2022...
Page 45
LED flashes red and the brightness is reduced. Test Images Pattern White / color bars / gray Select the test pattern to be displayed. bars / black Default: White Show... The selected pattern is displayed. CuratOR EX190 Instructions for Use, 06/2022...
Page 46
All automatically saved timing data and the following settings are deleted: • Brightness • Contrast • Backlight • Position (horizontal and vertical) • Zoom • Frequency • Phase • Interpolation filters • Color temperature CuratOR EX190 Instructions for Use, 06/2022...
When "Start" is selected, the start values for the timing are determined using "Execute func- tion". See also Determining the timing data [} 30] Execute function... When "Start" is selected in Mode, the set video resolution is executed. CuratOR EX190 Instructions for Use, 06/2022...
Note: When "Natural" is selected, only the value for • CIE (DIN 6174) Lmax can be changed. All other functions are hid- • den. • DICOM • Gamma 2.0, 2.2, 2.5, 2.7, 3.0, 3.3 • Log.Lum.linear Default: DICOM CuratOR EX190 Instructions for Use, 06/2022...
Page 49
When using the color setting based on the existing defaults, it is also possible to individually modify the Default: 0 (y = 0.308) color location. The Y color coordinate can be adapted using the "Y" function. Current target value (display only) Luminance (display only) CuratOR EX190 Instructions for Use, 06/2022...
Note: The function is displayed only if the "Back- light regulation" function is set to "Off". The control value is kept constant during operation. This means that the image becomes darker as the backlight ages CuratOR EX190 Instructions for Use, 06/2022...
This is required in the case of unstable signal sources, for example. Note: The disadvantage of the function is a delay of sev- eral milliseconds even for a desired timing change. The higher the value of the function, the greater the delay. CuratOR EX190 Instructions for Use, 06/2022...
Page 52
If the "PLL phase gain" is set too low or too high, distorted images will be displayed. Note: The best PLL phase gain can be obtained with the Pixel On/Off test pattern from a video test generator. CuratOR EX190 Instructions for Use, 06/2022...
Page 53
22 MHZ / 25 MHZ / Adjustable signal bandwidth for analog signals to filter out 30 MHZ / 38 MHz / high-frequency interference signals. 50 MHz / 75 MHz / 105 MHz / 149 MHz / 475 MHz Default: 475 MHz CuratOR EX190 Instructions for Use, 06/2022...
Misty Multi-Purpose Disinfectant Cleaner I and II Misty Disinfectant and Deodorant RTU (Amrep Inc.) Virex II 256 Precise Hospital Foam Cleaner Disinfectant "Green Soap" (soft soap) Water Tap water Demineralized water 1.6% liquid ammonia solution CuratOR EX190 Instructions for Use, 06/2022...
The picture quality of the monitor changes due to aging of the LCD unit and the backlight. • Check the monitor settings at regular intervals in accordance with the local guidelines. • Correct the settings if necessary. CuratOR EX190 Instructions for Use, 06/2022...
No error. The applied video signal was recognized. LED orange No video signal available. There are two possible causes: • No error. The monitor is in energy saving mode. • Error: The video source or video cable is damaged. CuratOR EX190 Instructions for Use, 06/2022...
Video modes with resolutions less than 1280 x 1024 can be expanded to the TFT resolution, and thus utilize the full display area. Timing recognition H frequency, V frequency, interlaced, number of horizontal lines CuratOR EX190 Instructions for Use, 06/2022...
5.1 +/- 0.5 kg (CuratOR EX190) 8.1 +/- 0.5 kg (CuratOR EX190-S) Dimensions (W x H x D) in mm 423 x 349 x 95 (CuratOR EX190) 423 x (447 ~ 529) x 208 (CuratOR EX190-S) CuratOR EX190 Instructions for Use, 06/2022...
Safety standards • IEC/EN 60601-1 • CAN/CSA - C22.2. No. 60601-1 • UL60601-1 • GB 4943.1, fuse T3.15A 250V Protection class Protection class I Degree of protection according to DIN 40050 IP20 Medical device classification (EU) Class 1 CuratOR EX190 Instructions for Use, 06/2022...
Dimension drawings 11.1 Monitor without stand 11 Dimension drawings All dimensions in mm 11.1 Monitor without stand Fig.: Views from front, top, and side Fig.: Rear view CuratOR EX190 Instructions for Use, 06/2022...
Dimension drawings 11.2 Monitor with stand 11.2 Monitor with stand Fig.: Views from front, top, and side CuratOR EX190 Instructions for Use, 06/2022...
Symbol for degree of protection according to DIN EN 60529. "On" symbol (voltage) "Off" symbol (voltage) Symbol "Comply with the instructions for use". Symbol for "Dangerous voltage". UK Responsible Person Swiss authorised representative (CH-REP) CuratOR EX190 Instructions for Use, 06/2022...
IEC/EN 60601-1-2. Electromagnetic radiation The CuratOR EX190 is intended for use in the electromagnetic environments noted below. Customers and users of the CuratOR EX190 have to ensure that the device is used in such an envi- ronment. Radiation test Conformity...
Page 64
The CuratOR EX190 was tested with the following compliance levels in accordance with the test re- quirements for professional healthcare facilities, as established in IEC/EN 6061-1-2. Customers and users of the CuratOR EX190 have to ensure that the monitor is used in such an envi- ronment.
Page 65
12.2 Information on electromagnetic compatibility (EMC) Electromagnetic interference immunity The CuratOR EX190 was tested with the following compliance levels in accordance with the test re- quirements for professional healthcare facilities, as established in IEC/EN 6061-1-2. Customers and users of the monitor have to ensure that the monitor is used in such an environment.
Page 66
Recommended minimum distance between portable or mobile RF communications devices and the CuratOR EX190 The CuratOR EX190 is intended for use in an electromagnetic environment in which interference due to electromagnetic radiation is controlled. For other portable and mobile RF communication devices (transmitters), the recommended minimum distance between the portable and mobile RF communi- cation devices (transmitters) and the monitor applies as listed below.
Page 67
Recommended minimum distance between portable or mobile RF communications devices and the CuratOR EX190 The CuratOR EX190 is intended for use in an electromagnetic environment in which interference due to electromagnetic radiation is controlled. The customer or user of the monitor can help prevent elec- tromagnetic interference by maintaining the recommended minimum distance between portable and mobile RF communications devices (transmitters) and the monitor.
Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. Note Use the specified cable below or EIZO signal cable with this monitor so as to keep interference within the limits of a Class B digital device. •...
EFUP shall be done in accordance with the Product Maintenance Procedures. This product must not be disposed of as unsorted municipal waste, and must be col- lected separately and handled properly after decommissioning. CuratOR EX190 Instructions for Use, 06/2022...
Page 70
Applications of hazardous substances in this medical device are required to achieve its intended clinical uses, and/or to provide better protection to human beings and/or to environment, due to lack of reasonably (economically or technically) available substitutes. 产品中有害物质的名称及含量 Table of hazardous substances’ name and concentration. CuratOR EX190 Instructions for Use, 06/2022...
12.5 Declaration of compliance with India RoHS 12.5 Declaration of compliance with India RoHS We, EIZO Corporation, hereby declare and guarantee that this product has been designed and manufactured in compliance with the E-Waste management rule 2016 which prohibit the inclusion of the following substances except for the exemptions listed in schedule II.
ENERGY STAR is a registered trademark of the United States Environmental Protection Agency in the United States and other countries. EIZO, the EIZO Logo, ColorEdge, CuratOR, DuraVision, FlexScan, FORIS, RadiCS, Radi- Force, RadiNET, Raptor and ScreenManager are registered trademarks of EIZO Corpora- tion in Japan and other countries.
Switch on 23 Features 14 Force Mode 26 Technical specifications 57 Timing Basic information 26 determining 30 General safety instructions 8 Troubleshooting 56 Grounding 17 User 7 Image position 24 Ventilation 15 Warranty 71 CuratOR EX190 Instructions for Use, 06/2022...
Need help?
Do you have a question about the CuratOR EX190 and is the answer not in the manual?