Figure 5: Rwt Connector Parts Of Set1 (Top: ¾" Version, Down: 1" Version) Ready For Mounting In The Rwt; Figure 6: Rwt Connector Parts Of Set1 (Top: ¾" Version, Down: 1" Version) Ready For Mounting In The Rwt - WaterBackpack PAUL Station Manual

Hide thumbs Also See for PAUL Station:
Table of Contents

Advertisement

®
PAUL
station
manual
¾" version:
Divide the pre-assembled connector as can be seen in Figure 5:
Figure 5:
RWT connector parts of set1 (top: ¾" version, down: 1" version) ready for
Make sure the threaded pipe with external thread is firmly screwed into the
threaded pipe with internal thread which also holds the filter cage on the other
side. Then place one of the seal on the threaded pipe with external thread, as
can be seen from the left side of Figure 5
From inside the tank, push this left part of the connector together with the seal
on the threaded pipe with external thread to the outer as far as possible.
Add the second seal on the threaded pipe with external thread.
Then tighten the connector with the counter nut on the threaded pipe, holding
tight the inner part of the connector.
Finally, screw the hose nozzle with cap nut on the threaded pipe.
1" version:
Divide the pre-assembled connector as can be seen in Figure 6.
Figure 6:
RWT connector parts of set1 (top: ¾" version, down: 1" version) ready for
PAUL Station Manual 2019-08-02
mounting in the RWT
mounting in the RWT
www.waterbackpack.org
2
1
02.08.2019
page 11