Figure 4: Rwt Connector Parts Of Set1 (Top: ¾" Version, Down: 1" Version) Pre-Assembled; Figure 5: Rwt Connector Parts Of Set1 (Top: ¾" Version, Down: 1" Version) Ready For Mounting In The Rwt - WaterBackpack PAUL Manual

Hide thumbs Also See for PAUL:
Table of Contents

Advertisement

PAUL station
manual
Figure 4:
RWT connector parts of set1 (top: ¾" version, down: 1" version) pre-assembled
Note:
In raw water, even if filterd at the pump inlet, there will be settleable solids. They will
accumulate at the bottom of the RWT. Thus, it is recommended to place the RWT
connector a little higher above the bottom of the RWT, as is shown qualitative in Fig-
ure 2, depending upon solids content in the raw water etc.
Also, the RWT should have a bottom outlet at the very lowest point of the tank to en-
able flushing out solids from time to time.
Although you are free to chose your most convenient way of mounting, we recommend the
following steps depending upon the diameter of the connector:
¾" version:
Divide the pre-assembled connector as can be seen in Figure 5:
Figure 5:
RWT connector parts of set1 (top: ¾" version, down: 1" version) ready for
Make sure the threaded pipe with external thread is firmly screwed into the threaded pipe
with internal thread which also holds the filter cage on the other side. Then place one of the
seal on the threaded pipe with external thread, as can be seen from the left side of Figure 5
PAUL Station Manual 2019-05-25
mounting in the RWT
page 9
25.05.2019