Set 3 Outlet Fwt; Figure 11: Set 3 Consisting Of Trank Connector And Ball Tap - WaterBackpack PAUL Station Manual

Hide thumbs Also See for PAUL Station:
Table of Contents

Advertisement

page 16
From the water meter a hose connection must be made to the float valve that
has to be mounted in the Filtered Water Tank to prevent from overfilling.
Drill a hole in the FWT close to the top of the FWT using the centre bit ½". Re-
move the outer nut and seal from the float valve and push the float valve to-
gether with the other seal and nut from inside the tank to the outer. Fasten the
valve with the seal and the nut you just had removed.
Note:
The water meter must be fixed in a horizontal position., see Figure 10.
Note:
The hose that connects
of 10 mm. This is essential. Do not use a hose with a bigger inner diameter, because
this could affect the flow of water through
Note:
Observe the height arrangements according to chapter 0.

4.3 Set 3 outlet FWT

In many cases, the outlets of the FWT will be provided locally. Nevertheless, set
3 can be obtained (also multiple, see note), consisting of a tank connector and a
ball tap, both ¾", see Figure 11 and also Figure 9Figure 10.

Figure 11: Set 3 consisting of trank connector and ball tap

Drill a hole in the FWT close to the bottom using the centre bit ¾". Then, push
the tank connector (1) together with the white seal from inside the tank to the
outer. Fasten the tank connector with the connecting nut using the screw
wrench AF 32 – please do not use any type of gripper, as the nut is made of
plastic.
Be sure to mount the tap on the tank connector with the inside thread!
PAUL Station Manual 2019-08-02
®
PAUL
with the FWT is white-blue and has an inner diameter
PAUL
www.waterbackpack.org
PAUL
®
!
®
station
manual
02.08.2019