Assembly; Set 1 To Connect The Raw Water Tank With Paul; Overview; Mounting The Tank Connector On The Raw Water Tank - WaterBackpack PAUL Station Manual

Hide thumbs Also See for PAUL Station:
Table of Contents

Advertisement

®
PAUL
station
manual
page 9

4 Assembly

®
4.1 Set 1 to connect the Raw Water Tank with
PAUL

4.1.1 Overview

Figure 3 shows how to connect all parts that come with set 1.
Figure 3:
All parts that come with set 1 and how to connect
On the left hand side the RWT connector can be seen. This connector comes
pre-assembled as can be seen in Figure 3.
Determine where to mount the filter. As this filter must be checked and – if
necessary – cleaned, see chapter 6.1.2, choose a location where the filter is
easily accessible, see also chapter 4.1.3. The valve is necessary to stop the
water flow during filter cleaning, so the valve should be mounted close to the fil-
ter.
Connect the RWT connector with the valve and then with the filter using the
blue hose.
®
Finally, connect the filter with the OPV or OPV-S mounted in
PAUL
using the
blue hose.

4.1.2 Mounting the tank connector on the Raw Water Tank

It might be a good idea to execute this step before you put the RWT in place.
Figure 4 shows the two versions of RWT connector. Due to the different diame-
ter, each complete connector consists of different parts as can be seen from the
figures and the list of parts in chapter 9.
The wall of the RWT must be between the two seals.