Making Frame Relay Connections
After the hardware is installed, use the addyred command to reconfigure the node to recognize the
card redundancy. Refer to the Cisco WAN Switching Command Reference for more information on
the commands addyred, delyred, dspyred, and ptyred.
Setting Up Frame Relay Ports and Connections (FRM)
This section outlines the steps for setting up and deleting Frame Relay ports, adding and configuring
connections, and bundling connections. As the steps show, some commands apply to channelized
connections (T1, E1, or J1) but not to unchannelized connections (V.35 or X.21). Use either the IGX
control terminal or a Cisco WAN Manager workstation to execute the commands. For parameters
and other details on the commands, refer to the Cisco WAN Switching Command Reference.
If a port has multiple PVCs, you can optionally bundle the connections. Bundling facilitates network
meshing. You can specify connection bundling during parameter specification in the Add
Connection (addcon) command: if you press Return without specifying a DLCI during port
specification, the system prompts for bundling information. See the "Frame Relay Connections"
chapter in the Cisco WAN Switching Command Reference for details.
Step 1
Step 2
Step 3
Note
100 ohms or 200 ohms. At higher speeds on ports with Y-cable redundancy, the impedance is
important. With Y-cable redundancy on a higher-speed connection, use the 200-ohm jumper card.
Without Y-cable redundancy or when the port speed is low, the 100-ohm jumper card is adequate.
Step 4
Step 5
Step 6
Step 7
Step 8
Step 9
3-34 Cisco IGX 8400 Series Installation and Configuration
If not already done, activate the applicable lines with the upln command.
Use the dspcds command to verify that all nodes have the correct FRI back card and FRM
front card. (Use the vt command to gain access to other nodes.) The dspcds output shows
the slot number of each card and any mismatch between firmware on the front card and
firmware on the back card. Note the slot number of each FRM or UFM for subsequent
commands.
For V.35 and X.21 interfaces, check the mode (DCE or DTE) of each relevant port by
using the dspfrport command. (For T1 and E1 lines, the mode is not applicable.) On an
FRI-X.25 or FRI-V.35 back card, a jumper board near each connector determines the
mode of the port. See the section "Port Mode Selection for V.35 and X.21" page 32.
Jumper cards for selecting the mode of a V.35 or X.21 interface have an impedance of either
For optional Y-cable redundancy, configure the two slots for redundancy by using
addyred.
For V.35 and X.21 interfaces, skip the next three steps.
For T1, E1, and J1 interfaces, bring up the line using the upln command.
For T1, E1, and J1 interfaces, configure the line using the cnfln command.
For T1, E1, and J1 interfaces, add the logical Frame Relay port using the addport
command.
For all interface types, activate the port using the upport command.
Configure the port for speed, clocking, LMI type, and so on, by using the cnffrport
command. Alternatively, you can keep the default parameters.
If you intend to bundle connections, use cnffrport to set the Port ID to the DLCI planned
at the near-end connections. Setting the PortID is optional for non-bundled connections.