Making Frame Relay Connections
FRI-X.21 has female DB-15 subminiature connectors.
Cabling requirements for the Frame Relay interfaces are in Appendix C, "Cabling Summary."
Take the following steps after you have inserted the cards according to the general information on
installing cards in the section "Preparing the Cards" page 1. To connect a cable:
Step 1
Step 2
Step 3
Record the slot number of each line. These numbers are necessary for configuring the system.
Port Mode Selection for V.35 and X.21
The position of a small jumper board at each port determines whether it is a DCE or a DTE.
Warning
Caution
grounding strap to your wrist, and clipping the wrist strap lead to the enclosure.
A small jumper card near each connector on the back card selects the port's mode. The factory-set
modes alternate between DCE and DTE. The steps that follow describe how to change the mode of
a port. The relation between back card row numbers and the port mode is as follows:
DCE=1, 2, 4, and 5 (jumper card is closest to the FRI faceplate)
DTE=2, 3, 5, and 6 (jumper card is one row away from the FRI faceplate)
Note
100 ohms or 200 ohms. At higher speeds on ports with Y-cable redundancy, the impedance is
important. With Y-cable redundancy on a higher-speed connection, use the 200-ohm jumper card.
Without Y-cable redundancy or when the port speed is low, the 100-ohm jumper card is adequate.
Note
card are carrying traffic, it disrupts service on the other ports.
To change the mode of an interface, reposition the jumper board for the port as follows:
Step 1
3-32 Cisco IGX 8400 Series Installation and Configuration
Bring each cable through the opening at the top or bottom of the cabinet (whichever
applies) and along the back of the unit.
If needed, use the cable manager to help route the cables.
Secure the cables to the connectors on the cards that mate with the correct front card.
Only qualified personnel should open the cabinet door.
To prevent damage to the FRI cards, ground yourself before handling IGX cards by clipping a
Jumper cards for selecting the mode of a V.35 or X.21 interface have an impedance of either
Carefully choose the mode for each port. If you change a port mode after other ports on the
If the FRI is already in the node:
Note its slot number.
Loosen the captive mounting screws on both ends of the faceplate.
Operate the card extractor levers and slide the card out.