Download Print this page

Cisco IGX 8400 Series Installation And Configuration Manual page 13

Cisco systems hub/switch installation and configuration guide
Hide thumbs Also See for IGX 8400 Series:

Advertisement

Removing Links from an IMA Feeder Group
To remove links from an IMA group, you can use either Cisco WAN Manager or the CLI. To remove
a link from an IMA group on the CLI:
Step 1
Step 2
Step 3
Step 4
Step 5
Note
UXM-E Inverse Multiplexing ATM IMA Lines
This feature allows the extension of the IMA protocol to UXM-E line interfaces, which substantially
reduces equipment and interface costs for customers requiring IMA line interfaces and trunks and
high bandwidth demand for ATM. It reduces costs by bundling multiple physical T1/E1 lines into a
logical line enlarging traffic bandwidth. This makes it unnecessary to upgrade access lines to higher
speed services such as T3/E3.
Note
(Release 9.2 and later SWSW). If the UXM IMA line is connected to another device, that device
must support ATM Forum Compliant IMA protocol, Version 1.0. To verify the UXM firmware
version, use the dspcd command.
To specify the range of ports for an IMA line, you can use either Cisco WAN Manager or the
command-line interface (CLI). To define an IMA line on the CLI, use the upln command:
upln slot.group-member
For example, you could enter upln 8.1–4. Subsequently, you would refer to this physical line by
using only the slot number and first group member—8.1 in this example—when you use commands,
such as upln, dnln, cnfln, and so on. Following the activation of an IMA line group, the logical port
will be created with the primary line port as the port number.
Commands for viewing IMA line information also include dsplncnf, dsplns, dspports, dspport,
dspphyslnstathist and dspphyslnstatcnf.
Note
device that supports the ATM Forum Compliant IMA Protocol, Version 1.0.
Find the nodes configured as trunks connected to the IMA feeder by using the dsptrks
command.
Reduce the number of retained links on the IMA feeder node.
Reduce the receive rate using the DS0 calculation on the IMA feeder node.
Repeat steps 2 and 3 on the IMA trunk.
Reduce the number of IMA group members on both trunk and feeder nodes by manually
entering the number of group members. Enter:
cnftrk slot.primary link
The primary link cannot be removed from an IMA group.
Both ends of the UXM-E IMA lines require you to install UXM-E Firmware Model B
The UXM-E IMA ports on an IGX, will interoperate with an IMA compliant router or a
Setting Up a UXM-E
Card Installation and Node Startup 3-13

Advertisement

loading