Kenwood CS-6040 Instruction Manual page 5

Quad trace readout oscilloscope
Table of Contents

Advertisement

S W E E P
T y p e
T y p e
T y p e
T y p e
T y p e
A
B
A
I N T
A L T
B
X - Y
S w e e p Time
S w e e p Time
A
B
S w e e p Magnification
Linearity
Holdoff
T r a c e Separation
Delay Method
Delay Time
Trigger Count
Delay Accuracy
Delay Jitter
T R I G G E R I N G
A Trigger Modes
A Trigger
A Trigger
A Trigger
A Trigger
A Trigger
A Trigger
V .
M O D E
Source
Source
Source
Source
Source
Source
c m
C H 2
C H 3
C H 4
L I N E
A Trigger Coupling
A Trigger Level
A Trigger Polarity
B Trigger Modes
B Trigger
B Trigger
B Trigger
B Trigger
CH1
Source
Source
Source
Source
C H 2
C H 3
C H 4
B Trigger Coupling
B Trigger Level
B Trigger Polarity
C S - 6 0 4 0
B s w e e p waveform is displayed a s an intensified portion of the A s w e e p .
A sweep (intensified for duration of B sweep) and B sweep (delayed sweep) alternating
2 0 ns/div to 0 . 5 s/div, ± 2 % ( 1 0 ° C to 3 5 ° C ) , in 2 3 ranges, in 1-2-5 sequence
Vernier control provides fully adjustable s w e e p time all ranges.
2 0 ns/div to 5 0 ms/div, ± 2 % ( 1 0 ° C to 3 5 ° C ) , in 2 0 ranges, in 1-2-5 sequence
Vernier control provides fully adjustable s w e e p time all ranges.
x 10 (ten times) ± 5 % ( A and B)
2 0 ns/div to 0 . 5 s/div : ± 3 % ( ± 5 % , at x 10 M A G )
Continuously variable for A sweep from N O R M to more than five times
B s w e e p can be separated from A s w e e p up to 4 divisions d o w n w a r d ,
Continuous delay, Trigger delay and Trigger count
Continuous delay, Trigger delay ; 0.2 to 10 times of A S W E E P T I M E / D I V set value
1 to 2,000 count, Max. usable frequency; 10 MHz
± (2% of set value + 1 % of fullscale) + (0 to 100 ns)
Triggered by input signal selected with V E R T I C A L M O D E selector
Triggered by CH1 vertical axis input signal
Triggered by C H 2 vertical axis input signal
Triggered by C H 3 vertical axis input signal
Triggered by C H 4 vertical axis input signal
A C ,
N O I S E R E J , H F R E J , D C , T V F R A M E , (In T V C O U N T mode,
enables switching between F L D 1 / F L D 2 and 5 2 5 / 6 2 5 lines.), T V L I N E
Sterts After Delay, B Triggerable After Delay and T R I G
Triggered by CH1 vertical axis input signal
Triggered by C H 2 vertical axis input signal
Triggered by C H 3 vertical axis input signal
Triggered by C H 4 vertical axis input signal
A C ,
A s w e e p
B s w e e p
X - Y oscilloscope
continuously adjustable.
( 5 , 0 0 0 count fullscale)
1/20,000
A U T O , N O R M , S I N G L E , F I X
Triggered by line frequency
± 9 0 ° adjustable
+ / -
N O I S E R E J , H F R E J , D C , T V
L I N E
± 9 0
0
adjustable
+ / -
C S - 6 0 3 0
C O U N T
5

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cs-6030

Table of Contents