Kenwood CS-6040 Instruction Manual page 12

Quad trace readout oscilloscope
Table of Contents

Advertisement

(§) CH4 T POSITION Control
Adjusts vertical position of channel-4 waveform dis-
played on the C R T . Also used to adjust the Y - a x i s posi-
tion in the X - Y operation.
© CH4 0.5 V/0.1 V Switch
Vertical attenuator of channel 4 . Provides the same func-
tion as the C H S 0 . 5 V / 0 . 1 V s w i t c h @ for channel 4 .
@ C U R S O R S Switches
Selects the cursor measurement modes.
If four L E D s are off, the cursor measurement mode is
deactivated; the cursor, cursor measurement mode, and
cursor measurement value are not displayed on the C R T .
To deactivate the cursor measurement mode, press a
lighting s w i t c h .
N O T E : The cursor measurement is impossible for some
items, depending on combination of the V E R T I C A L
MODE © and HORIZONTAL MODE (§) switches.
For details, refer to operating instructions.
AV\:
Activates zlV1 and A\/3 cursor measurement. Cur-
sor measurement is activated w h e n any of C H 1 ,
C H S , and A D D of the V E R T I C A L MODE s w i t c h e s
@ is selected. Order of measurement priority of
these three channels is C H 1 , C H 3 , and A D D . T w o
horizontal cursors are displayed on the C R T . Vol-
tage difference and voltage ratio of these cursors
are displayed posterior to the cursor measurement
mode in the upper right of the C R T .
The AV\
cursor is used for voltage
measurement, if the C H 1 V A R I A B L E control @ is
set to the C A L position. A value calculated accord-
ing to setting of the C H 1 V O L T S / D I V control ® is
displayed posterior to the / I V 1 .
Voltage ratio is measured if the C H 1 V A R I A B L E
control @ is not set to the C A L position; a value
calculated supposing 5 div. as 1 0 0 % is displayed
posterior to the R A T I O .
12
Fig. 3
In the 4 V 3 cursor measurement, a value calculat-
ed according to setting of the C H S 0 . 5 V / 0 . 1 V is
displayed posterior to the A\/3.
If the A D D of the V E R T I C A L MODE s w i t c h e s < § >
is selected, voltage difference (ziV1) is measured
under the condition where the C H 1 V O L T S / D I V
control © and C H 2 V O L T S / D I V control © are set
to the same level as well as the V A R I A B L E control
© and © are set to C A L . Otherwise, voltage ratio
(RATIO) is measured.
If the zicursor is below the z l R E F cursor, a nega-
tive ( - ) value is displayed.
AV2: Activates A\/2 and AV4 cursor measurement when
C H 2 or C H 4 of the V E R T I C A L MODE s w i t c h e s <§)
is selected. Order of measurement priority of these
t w o channels is C H 2 and C H 4 . T w o horizontal cur-
sors are displayed on the C R T . Voltage difference
and voltage ratio of these cursors are displayed
posterior to the cursor measurement mode in the
upper right of the C R T .
The z l V 2 cursor is used for voltage difference
measurement, if the C H 2 V A R I A B L E control @ is
set to C A L position. A value calculated according
to setting of the C H 2 V O L T S / D I V control © is dis-
played posterior to the AV2.
Voltage ratio is measured if the C H 2 V A R I A B L E
control @ is not set to the C A L position; a value
calculated supposing 5 div. as 1 0 0 % is displayed
difference
posterior to the R A T I O .
In the A\/4 cursor measurement, a value calculat-
ed according to setting of the C H 4 0 . 5 V / 0 . 1 V
s w i t c h is displayed posterior to the z3V4.
If the zlcursor is below the ^ R E F cursor, a nega-
tive ( - ) value is displayed.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cs-6030

Table of Contents