Kenwood CS-6040 Instruction Manual page 20

Quad trace readout oscilloscope
Table of Contents

Advertisement

5 CH2 Scale Factor
Displays the channel-2 vertical axis sensitivity for 1 div.
In the U N C A L condition, a " > " is displayed before the
channel-2 vertical axis sensitivity.
grounded, however, a " jfr " mark is displayed but no
" > " is displayed even in the U N C A L condition.
If the A C - D C s w i t c h is set to A C for channel 2, a " ~ "
mark is displayed above the unit of the vertical axis sen-
sitivity.
NOTE: No display is provided unless C H 2 or ADD of the
V E R T I C A L MODE s w i t c h e s © is selected.
However, if X - Y of the H O R I Z O N T A L MODE
s w i t c h e s ©
is selected, display is provided,
regardless of V E R T I C A L MODE setting.
6 CH3 Scale Factor
Displays the channel-3 vertical axis sensitivity for 1 div.
NOTE: No display is provided unless C H 3 of the V E R -
T I C A L MODE s w i t c h e s © is selected.
7 CH4 Scale Factor
Displays the channel-4 vertical axis sensitivity for 1 div.
NOTE: No display is provided unless C H 4 of the V E R -
T I C A L MODE s w i t c h e s © is selected.
8
ADD
Displays a " + " mark if A D D of the V E R T I C A L MODE
s w i t c h e s © is selected.
9 C H 2 Invert
Displays a "
\ " mark if C H 2 INV of the V E R T I C A L
MODE s w i t c h e s © is selected.
1 0
A Sweep Scale Factor
Displays a range of the A s w e e p set with the S W E E P
T I M E / D I V control © .
Displays a " > " before the A s w e e p range if the A
S W E E P T I M E / D I V control © is set to the U N C A L con-
dition.
11
B Sweep Scale Factor
Displays a range of the B s w e e p set with the S W E E P
T I M E / D I V control © .
Displays a " > " before the B s w e e p range if the B
S W E E P T I M E / D I V control © is set to the U N C A L con-
dition.
N O T E : If X - Y of the H O R I Z O N T A L MODE s w i t c h e s ©
is selected, A and B scale factors disappear and
" C H 2 - X " is displayed.
20
If channel-2 is

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cs-6030

Table of Contents