[Water-cooled Models]
1) Turn off the power supply and wait for 3 minutes.
2) Turn on the power supply and wait for 20 seconds.
3) Close the Water Supply Line Shut-off Valve.
4) Open the Drain Valve and quickly blow the water supply line from the Drain Valve to drain
water in the Condenser.
5) Follow the above steps 3) through 11) in [Remote Air-cooled Models].

2. CLEANING INSTRUCTIONS

1. HOSHIZAKI recommends cleaning this unit at least once a year. More
frequent cleaning, however, may be required in some existing water
conditions.
2. To prevent injury to individuals and damage to the icemaker, do not use
ammonia type cleaners.
3. Always wear liquid-proof gloves for safe handling of the cleaning and
sanitizing solution. This will prevent irritation in case the solution comes
into contact with skin.
<STEP 1>
Dilute the solutions with water as follows.
Cleaning solution: 4.8 fl. oz. of recommended cleaner Hoshizaki "Scale Away" or
Sanitizing solution:
For safety and maximum effectiveness, use the solution immediately after
dilution.
"LIME-A-WAY" (Economics Laboratory, Inc.) with 0.8 gal. of water.
This is a minimum amount. Make more solution, if necessary.
2.5 fl. oz. of a 5.25 % sodium hypochlorite solution (chlorine bleach) with
5 gal. of water.