Cleaning; Transport; Storage - Scheppach HL760LS Original Instruction Manual

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 21
The customer's mains connection as well as the ex-
tension cable used must also comply with these reg-
ulations.
Damaged electrical connection cable
The insulation on electrical connection cables is often
damaged.
This may have the following causes:
• Passage points, where connection cables are
passed through windows or doors.
• Kinks where the connection cable has been improp-
erly fastened or routed.
• Places where the connection cables have been cut
due to being driven over.
• Insulation damage due to being ripped out of the wall
outlet.
• Cracks due to the insulation ageing.
Such damaged electrical connection cables must not
be used and are life-threatening due to the insulation
damage.
Check the electrical connection cables for damage
regularly. Make sure that the connection cable does
not hang on the power network during the inspection.
Electrical connection cables must comply with the ap-
plicable VDE and DIN provisions. Only use connection
cables with the marking H05VV-F.
The printing of the type designation on the connection
cable is mandatory.
For single-phase AC motors, we recommend a fuse
rating of 16A (C) or 16A (K) for machines with a high
starting current (starting from 3000 watts)!
DIN EN 61000-3-11
• The product meets the requirements of
EN 61000- 3-11 and is subject to special connection
conditions. This means that use of the product at any
freely selectable connection point is not allowed.
• Given unfavorable conditions in the power supply
the product can cause the voltage to fluctuate tem-
porarily.
• The product is intended solely for use at connection
points that
a. do not exceed a maximum permitted supply im-
pedance "Zmax = 0.331 Ω", or
b. have a continuous current-carrying capacity of
the mains of at least 100 A per phase.
28 | GB
• As the user, you are required to ensure, in consulta-
tion with your electric power company if necessary,
that the connection point at which you wish to oper-
ate the product meets one of the two requirements,
a) or b), named above.
AC motor 230 V/ 50 Hz
Mains voltage 230 Volt / 50 Hz.
The mains connection and the extension cable have to
be three-core cables = P + N + SL. - (1/N/PE).
Extension cables of up to 25 m must have a minimum
cross-section of 1.5 mm².
Mains fuse protection is 16 A maximum.

12. Cleaning

Attention!
Pull out the power plug before carrying out any clean-
ing work on the equipment.
We recommend that you clean the equipment immedi-
ately after you use it.
Clean the equipment regularly with a damp cloth and
some soft soap. Do not use cleaning agents or sol-
vents; these may be aggressive to the plastic parts in
the equipment. Ensure that no water can get into the
interior of the equipment.

13. Transport

The log splitter is equipped with two wheels for easy
transport.
The machine can be transported on the wheels at an
angle. Use the transport handle, lift and pull or push.
(fig. 16)

14. Storage

Store the device and its accessories in a dark, dry and
frost-proof place that is inaccessible to children. The
optimum storage temperature is between 5 and 30˚C.
Store the tool in its original packaging. Cover the elec-
trical tool in order to protect it from dust and moisture.
Store the operating manual with the power tool.
www.scheppach.com

Advertisement

Table of Contents
loading

This manual is also suitable for:

5905211934

Table of Contents