5.6.2 Electrical Wiring
(1). For solid core wiring (Fig. 4.26)
1). Cut the wire end with a wire cutter or wire-cutting pliers, then strip the
insulation about 25
2). Using a screwdriver, remove the terminal screw(s) on the terminal board.
3). Using pliers, bend the solid wire to form a loop suitable for the terminal screw.
4). Shape the loop wire properly, place it on the terminal board and tighten
securely with the terminal screw using a screwdriver.
(2). For strand wiring (Fig. 4.26)
1). Cut the wire end with a wire cutter or wire-cutting pliers, then strip the
insulation about 10 mm (3/8") .
2). Using a screwdriver, remove the terminal screw (s) on the terminal board.
3). Using a round terminal fastener or pliers, securely clamp a round terminal to
each stripped wire end.
4). Position the round terminal wire, and replace and tighten the terminal screw
with a screwdriver.(Fig. 4.27)
Fig. 4.27
(3). How to fix connection cord and power cord by cord clamp
After passing the connection cord and power cord through the insulation tube,
fasten it with the cord clamp.(Fig. 4.28)
DC Inverter U-match Series Floor Ceiling Type Unit
mm (15/16") .
Fig. 4.26
27
Fig. 4.28