Fan-motor assembly is not cased allowing back return or bottom return installations. High Efficiency Heat Exchanger A boundary layer film of air adhering to the fin surface will insulate the fin surface and severally reduces the heat exchange efficiency. Mcquay slit fin design eliminates this boundary layer of air and creates continuous for best heat exchange efficiency. Variable External Static Pressure Four types of external static pressure are available for every unit:0PA, 30Pa,,60Pa,80Pa.
Electrical Data (50Hz) MCW-C/H/F MODEL MCW200 MCW300 MCW400 MCW600 MCW800 MCW1000 MCW1200 INSuLATION GRADE/IP E/0 POWEr SOUrCE V/Ph/Hz 0~40/1/50 rATED INPUT POWEr MOTOr rATED rUNNING CUrrENT 0.10 0.15 0.0 0.30 0.47 0.48 0.60 POLES INSuLATION GRADE/IP E/0 POWEr SOUrCE V/Ph/Hz...
Electrical Data (60Hz) MCW-C/H/F MODEL MCW200 MCW300 MCW400 MCW600 MCW800 MCW1000 MCW1200 INSuLATION GRADE/IP E/0 POWEr SOUrCE V/Ph/Hz 115/1/60 rATED INPUT POWEr MOTOr rATED rUNNING CUrrENT 0.30 0.41 0.49 0.77 1.00 1.15 1.50 POLES INSuLATION GRADE/IP E/0 POWEr SOUrCE V/Ph/Hz...
Electrical wiring connection must be done according to the wiring diagram on the unit. The unit must be GROUNDED to the earth system of the building. All field wiring must be installed in accordance with the national wiring regulation and Fire Department regulation. FOR MODEL: MCW200 MCW300 MCW400 MCW600 (0Pa and 30Pa) WIRING ORANGE BLACK...
Page 31
FOR MODEL: MCW200 MCW300 MCW400 MCW600 (60Pa and 80Pa) WIRING ORANGE BLACK BROWN BLACK YELLOW FAN SPEED SWITCH POWER BLUE SOURCE MAIN SWITCH NOTE: FIELD WIRING MF: FAN SPEED MEDIUM M~: FAN MOTOR HF: FAN SPEED HIGH LF: FAN SPEED LOW SHF: FAN SPEED SUPER HIGH 60Pa: LF—Low Speed MF—Medium Speed HF—High Speed...
Installation receiving All units leaving the McQuay plant have been inspected to ensure the shipment of high quality products and reasonable means are utilized to properly pack the fan coil units to protect them in transit. Carefully inspect all shipments immediately upon delivery. When damage is visible, note this fact on the carrier’s freight bill and request that the carrier sends a representative to inspect the damage.
Page 33
Fig.2 WITH AND WITHOUT PLENUM FOrM: Fig.3 DETAIL A: Air Duct Connection Circulatory air pressure drop should be within External Static Pressure Galvanized steel air ducts are suitable Make sure there is no leak of air. Air duct should e fireproof, refer to concerned country national and local regulations. Pipe Connection Using suitable fittings as water pipe connections. Refer to the specification The water inlet is on the bottom while outlet on top.
MCW400C/H/F M01014060317 TOP PLATE MCW600C/H/F M0101406030 TOP PLATE MCW800C/H/F M0101406033 TOP PLATE MCW1000C/H/F M0101406036 TOP PLATE MCW100C/H/F NOTE: “NEED SELECTION” PARTS PLEASE FIND THE REFERENCEMENT MATERIAL MARKED AS FOLLOWING: Item4.Blower Centrifugal MODEL & QUANTITY SELECTION DESCrIPTION MCW200 MCW300 MCW400 MCW600 MCW800 MCW1000 MCW1200 C/H/F C/H/F C/H/F C/H/F C/H/F C/H/F C/H/F M0309000980 BLOWER CENTRIFUGAL SYP160/00J-L BLOWER CENTRIFUGAL M0309000981...
Page 35
DESCrIPTION M0309000980 BLOWER CENTRIFUGAL SYP160/200J-L M0309000981 BLOWER CENTRIFUGAL SYP160/200J-R Item5.Drainpan DESCrIPTION NOTE MODEL SELECTION QUANTITY M50014063167 DRAINPAN STANDARD LENGTH.PE INSULATION MCW00C/H/F M50014063168 DRAINPAN STANDARD LENGTH.PE INSULATION MCW300C/H/F M50014063169 DRAINPAN STANDARD LENGTH.PE INSULATION MCW400C/H/F M50014063170 DRAINPAN STANDARD LENGTH.PE INSULATION MCW600C/H/F M50014063171 DRAINPAN STANDARD LENGTH.PE INSULATION MCW800C/H/F M5001406317 DRAINPAN STANDARD LENGTH.PE INSULATION MCW1000C/H/F M50014063173 DRAINPAN STANDARD LENGTH.PE INSULATION MCW100C/H/F M50014063738 DRAINPAN LENGTH EXTENDED100mm.PE INSULATION MCW00C/H/F M50014063739 DRAINPAN LENGTH EXTENDED100mm.PE INSULATION MCW300C/H/F...
Page 36
Item 10.Motor MOTOr 1 MOTOr 2 STATIC PrES- MODEL DESCrIPTION PArT NUMBEr DESCrIPTION SUrrE 0 Pa M03034065037 MOTOR, YDK7-6B4 MCW00 C/H/F 30 Pa M03034065041 MOTOR, YDK10-4B4 60/80 Pa M03034065045 MOTOR, YDK22-4B4 0 Pa M03034065038 MOTOR, YDK10-6B4 MCW300 C/H/F 30 Pa M0303406504 MOTOR, YDK16-4B4 60/80 Pa M03034065046 MOTOR, YDK32-4B4 0 Pa M03034065039 MOTOR, YSK16-6B4...
Guide Specifications Unit Description Factory-assembled, horizontal, blow-thru type, galvanized casing, ceiling ducted fan coil unit is complete with water coil, fans, motors, drain pan, filters and all required wiring, with full access to internal components. Quality Assurance Each coil is factory tested for leakage at 3.3MPa air pressure with coil submerged in water. Each unit and its moving components (fans and motors) are factory computer-tested and recorded after unit is complete and before it is packed.
Page 38
Products manufactured in an ISO certified facility. This document contains the most current product information as of this printing. For the most up-to-date product information, please go to www.mcquay.com.cn. 2006 McQuay International +1 (800) 432-1342 www.mcquay.com...