Electrical Box
Step
6
Disconnect the
connector [S70].
Disconnect the
7
connector [S20] [S40]
[S80] [S90].
Disconnect the relay
8
connector for the
compressor.
9
Disconnect the 2
connectors for the
reactor.
4
Procedure
[S70]
[S40] [S90] [S20] [S80]
Points
[S70]: fan motor
(R0254)
[S20]: electronic expansion
valve coil
[S40]: overload protector
[S80]: four way valve coil
[S90]: thermistors
(R18668)
(R0259)
When reassembling, you
can connect the 2 harnesses
in either way regardless of
the color.
(R0260)
Removal Procedure