Line Cards
An AC-input power supply has the following features (see
Note
Table 1-9
LED Label
AC
Cisco XR 12406 Router Installation Guide
1-32
Original series Cisco XR 12406 Routers: A power factor corrector (PFC)
allows the power supply to accept AC power source voltage from an AC
power source operating from 100 to 120 VAC 20-amp service in North
America, and a range of from 185 to 264 VAC 16-amp service in an
international environment.
Enhanced series Cisco XR 12406 Routers: Supports 220 VAC only which
requires 20-amp service in North America, and 16-amp service in an
international environment.
Each AC-input power supply weighs approximately 14 pounds (6.4 kg), and
can deliver up to 1400 W for original versions, or up to 1950 W for enhanced
versions of the router.
Each AC-input power supply requires a dedicated 20A service in North
America (16 A international).
A power standby switch on the faceplate temporarily disables the DC output
power circuitry in the AC-input power supply.
This switch does not interrupt the incoming AC power in the AC-input
power supply. Portions of the power supply circuitry are still under
AC power as long as AC power is connected to the router.
A handle is provided for ease in removing and replacing the power supply.
Captive screws on the power supply ejector levers secure it in the power
supply bay.
Two LEDs on the faceplate to provide status information.
summarizes the function of these indicators.
AC-Input Power Supply LED indicators
Function
Input
power
Chapter 1
State
Description
On
AC power source is present and is within
specified limits.
Off
Power source is not within specified
limits.