5.8.5 Normal vibration levels, alarm and trip
For guidance, pumps generally fall under a
classification for rigid support machines within the
International rotating machinery standards (API 610,
latest ed./ISO 13709, latest ed.) and the
recommended maximum levels below are based on
those standards.
Alarm and trip values for installed
pumps should be based on the actual measurements
(N) taken on the pump in the fully commissioned as
new condition. Measuring vibration at regular
intervals will then show any deterioration in pump or
system operating conditions.
Vibration velocity – unfiltered
mm/s (in./s) r.m.s.
Normal
N
Alarm
N x 1.25
Shutdown trip N x 2.0
5.8.6 Stop/start frequency
Pump sets are normally suitable for the number of
equally spaced stop/starts per hour shown in the table
below. Check actual capability of the driver and
control/starting system before commissioning.
Motor rating kW (hp)
Up to 15 (20)
Between 15 (20) and 90 (120)
Above 90 (120)
Where duty and standby pumps are installed it is
recommended that they are run alternately every
week.

5.9 Stopping and shutdown

a)
Close the outlet valve, but ensure
that the pump runs in this condition for no more
than a few seconds.
b) Stop the pump.
c) Switch off flushing and/or cooling/heating liquid
supplies at a time appropriate to the process.
d)
For prolonged shut-downs and
especially when ambient temperatures are likely
to drop below freezing point, the pump and any
cooling and flushing arrangements must be
drained or otherwise protected.
5.10 Hydraulic, mechanical and electrical
duty
This product has been supplied to meet the
performance specifications of your purchase order,
however it is understood that during the life of the
product these may change. The following notes may
help the user decide how to evaluate the implications
PVML USER INSTRUCTIONS ENGLISH 00079591 – 01/05
Overhung pumps
≤ 3.0 (0.12)
≤ 3.9 (0.15)
≤ 4.5 (0.18)
Maximum stop/starts
per hour
15
10
6
Page 17 of 29
of any change. If in doubt contact your nearest
Flowserve office.
5.10.1 Specific gravity (SG)
Pump capacity and total head in metres (feet) do
not change with SG, however pressure displayed
on a pressure gauge is directly proportional to SG.
Power absorbed is also directly proportional to SG.
It is therefore important to check that any change in
SG will not overload the pump driver or over-
pressurize the pump.
5.10.2 Viscosity
For a given flow rate the total head reduces with
increased viscosity and increases with reduced
viscosity. Also for a given flow rate the power
absorbed increases with increased viscosity, and
reduces with reduced viscosity. It is important that
checks are made with your nearest Flowserve
office if changes in viscosity are planned.
5.10.3 Pump speed
Changing pump speed effects flow, total head,
power absorbed, NPSH
Flow varies in direct proportion to pump speed,
head varies as speed ratio squared and power
varies as speed ratio cubed. The new duty,
however, will also be dependent on the system
curve. If increasing the speed, it is important
therefore to ensure the maximum pump working
pressure is not exceeded, the driver is not
overloaded, NPSH
> NPSH
A
vibration are within local requirements and
regulations.
5.10.4 Net positive suction head (NPSH
NPSH available (NPSH
available in the pumped liquid, above its vapour
pressure, at the pump suction branch.
NPSH required (NPSH
R
required in the pumped liquid, above its vapour
pressure, to prevent the pump from cavitating. It is
important that NPSH
> NPSH
A
between NPSH
> NPSH
A
possible.
If any change in NPSH
A
margins are not significantly eroded. Refer to the
pump performance curve to determine exact
requirements particularly if flow has changed. If in
doubt please consult your nearest Flowserve office
for advice and details of the minimum allowable
margin for your application.
5.10.5 Pumped flow
Flow must not fall outside the minimum and
maximum continuous safe flow shown on the pump
performance curve and or data sheet.
, noise and vibration.
R
, and that noise and
R
)
A
) is a measure of the head
A
) is a measure of the head
. The margin
R
should be as large as
R
is proposed, ensure these