Disconnecting Cables From The Lineage Ac-Dc Power Shelf And The Cisco Ubr10012 Router; Connecting Dc Power To The Cisco Ubr10012 Router - Cisco Universal Broadband Router uBR10012 Hardware Installation Manual

Cisco systems universal broadband router hardware installation guide
Hide thumbs Also See for Universal Broadband Router Cisco uBR10012:
Table of Contents

Advertisement

Connecting DC Power to the Cisco uBR10012 Router

Disconnecting Cables from the Lineage AC-DC Power Shelf and the
Cisco uBR10012 Router
To disconnect cables from the Lineage AC-DC power shelf and the Cisco uBR10012 router:
Ensure that the power is turned off on the power shelf by disconnecting the power supply at the facility
Caution
before proceeding to disconnect the other cables.
1.
1.
2.
3.
4.
Connecting DC Power to the Cisco uBR10012 Router
This section describes how to connect the Cisco uBR10012 router to the two –48/–60 VDC power
sources that provide its operating power. The DC power sources can either be already present at the site,
or they can be provided by the external AC-input power shelves. If using the external 2400 W AC-input
power shelf, be certain you have already installed it, as described in the
Installation
For full power redundancy, each terminal block on the external power shelf must be connected to a
Note
separate power source. If using the optional 2400 W AC-input power shelf, full power redundancy also
requires that each of the AC power supplies in the shelf be connected to AC power sources that are on
separate circuit breakers.
Warning
A readily accessible two-poled disconnect device must be incorporated in the fixed wiring. Statement
91
Warning
Connect the unit only to DC power source that complies with the safety extra-low voltage (SELV)
requirements in IEC 60950 based safety standards. Statement 1033
Secure all power cabling when installing this unit to avoid disturbing field-wiring connections.
Warning
Statement 38
Cisco uBR10012 Universal Broadband Router Hardware Installation Guide
3-34
Power off the power shelf by disconnecting the power supply at the facility. Wait a few minutes
before disconnecting the power cables so that they discharge.
Disconnect the AC cables from the standard wall socket. Disconnect the AC power cables from each
of the AC-input power supply sources on the power shelf.
Disconnect the alarm monitor cable from the J1 housing on the power shelf, and from the alarm input
connectors on the DC PEM modules of the Cisco uBR10012 router.
Disconnect the DC power cables on each side of the DC power sources, on the power shelf.
Disconnect the other ends of the DC power cable from the DC power terminal blocks of the
Cisco uBR10012 router.
Guide.
Chapter 3
Installing the Cisco uBR10012 Router
2400 W AC-Input Power Shelf
OL-18259-09