Technical data

13. Technical data
13.1. Power heat pump
Nominal volume
Maximum power
(HP* + supplementary heater)
Air temperature range
Hot water temperature
with heat pump
Power consumption of the
heat pump, max.
Sound pressure level at 1 m**
Refrigerant
GWP value (CO
equivalent)
2
Air-technical connection type
13.2. Standard data EN 16147
Withdrawal cycle
COP*
Electrical reserve power
Reference domestic hot
water temperature
Heat-up time
Energy efficiency class
Seasonal energy efficiency
Vmax
V40 td
13.3. Dimensions and connections
Dimensions
Weight (empty)
CW and DHW connection
diameter
Power supply
Degree of protection
Circuit breaker (curve D)
Frequency range***
HR power***
13.4. Cylinder
Materials and protection
Operating pressure, max.
Condensate throughput, max.
Power integrated supple-
mentary electric heating
system (Safety = 85 °C)
Temperature with supplem.
electric heating system, max.
* DHW = domestic hot water
* CW = cold water
** Sound pressure tested in a low-reflection room
*** When equipped with wireless option
www.dimplex.de
l
250
W
1900
°C
5 to 35 °C
°C
40 to 60°C
W
700
dB(A)
37
- / kg
R 290 / 0.150
0.45 kg CO
kg
2
-
Indoor air
-
l
-
3.2
W
32
°C
53.8
-
08:00
-
A+
%
133
l
321
l
713
mm
630 x 1721
kg
82
Inch
3/4
V/Hz/A
230 V/50 Hz/8 A
-
IPX1
A
13 A
MHz
868 - 868.6
dBm
10.65
-
Enamelled steel
MPa
0.6 (6 bar)
l/h
0.3
W
1200
°C
70
HP = heat pump
COP = coefficient of performance
13.5. Dimensions
ATTENTION!
Heavy shipping weight.
FD 0207