Advertisement

TENS Unit
Model: ETU-134
User Manual
Questions or Concerns?
support@etekcity.com • (855) 686-3835
1

Advertisement

Table of Contents
loading

Summary of Contents for ETEKCITY TENS Unit

  • Page 1 TENS Unit Model: ETU-134 User Manual Questions or Concerns? support@etekcity.com • (855) 686-3835...
  • Page 2 If you have any questions or concerns, please reach out to our helpful Customer Support Team at support@etekcity.com. We hope you enjoy your new TENS unit! BECOME AN ETEKCITIZEN Get exclusive deals, giveaways, and product registration. Better products for better living.
  • Page 3: Table Of Contents

    2 x Electrode Pads (50 x 100 mm) Digital Display 4 x Lead Wires Controls 1 x Micro USB Cable Getting to Know Your TENS Unit 1 x User Manual • Controlling Pain 1 x Quick Start Guide • Length and Intensity •...
  • Page 4: Specifications

    Specifications Frequency 1–100Hz Pulse Width 70–300µs 0–60V±20% (at 1000 load) Output Voltage Output Intensity level 0~20 levels Electrode Connection Type Pigtail Operation Time 10–60 minutes 5.5 x 2.5 x 0.6 in / Dimensions 138.8 x 63.3 x 15.5 mm Weight 3.2 oz / 96 g Temperature: 41°F–104°F / 5°C–40°C Operating Environment...
  • Page 5 Battery Type 3.7V, 250mAh Li-ion battery Rated Power 4.2V 3 hours Charging Time Automatic Shutoff 3 minutes TENS Unit: 3 years Service Life Electrodes: 10–15 uses IP Code IP22 Internally powered(operating) / Class II (charging)/ Classification of ME Equipment: Continuous operation...
  • Page 6: Safety Information

    Contraindication disturbances to heart rhythm in certain individuals. • Do not use the TENS unit if you have or use You have had or are using medical or cardiac pacemakers, implanted defibrillators, physical treatment for your pain. respirators, electrocardiographs, or any...
  • Page 7 • Do not use the TENS unit on your chest. The • Do not use the TENS unit in the bath or shower. TENS unit uses electrical currents. Using the The TENS unit is not waterproof, and a humid TENS unit on your chest may cause rhythm environment may damage it, resulting in disturbances to your heart, which could be lethal.
  • Page 8 • Because the effects of electrical stimulation on not correctly applied, this may result in the brain are unknown, do not use the TENS unit discomfort or skin burns. on your head. 2. If you do not know if the electrode pads •...
  • Page 9 TENS unit. objects, such as belt buckles or jewelry. • Do not use the TENS unit within 3.3 ft / 1 m from • Use the TENS unit only with the electrodes and shortwave or microwave medical equipment.
  • Page 10 • You may get a headache or other pain if you use electromagnetic interference. the TENS unit near your eye, or on your head or Do not use while charging. Unplug the power • face.
  • Page 11: Function Diagram

    Function Diagram Display A Channel Intensity Increase/Decrease Therapy Modes [15] Time Button Lead Wires Battery Indicator B Channel Intensity Increase/Decrease Power/Pause Button A1 Output A2 Output Micro USB Port B1 Output B2 Output Electrode Pad Micro USB Cable...
  • Page 12: Digital Display

    Digital Display Time Display A Channel Intensity Level Body Part Icons Program Number Pause Icon B Channel Intensity Level Kneading Icon ACU (Acupuncture) Icon Tap Icon Cupping Icon Scraping Icon Random Icon...
  • Page 13: Controls

    Press to increase time in 10-minute increments. Massage Type: Press to select the massage type. The selection will flash on the display and show the Note: When you first turn on the TENS unit, corresponding number. the default time will be 20 minutes. Knead...
  • Page 14: Getting To Know Your Tens Unit

    It should be applied to normal, healthy, and Use the TENS unit as soon as your pain begins. Start dry skin of adult patients. with 1 session. If you address your pain early, it may...
  • Page 15: Length And Intensity

    30 minutes for each treatment area. Depending on • You experience an adverse reaction such as the level of pain, you may use the TENS unit up to 3 skin irritation, redness, burns, headaches, other times a day for a maximum of 90 minutes total. Do painful sensations, or any increased discomfort.
  • Page 16: Using The Tens Unit

    Using the TENS Unit Note: Before first use, fully charge the TENS unit Gently peel the pads from the plastic and place at (see Charging the Battery, page 21). least 2 in / 5 cm apart on clean, dry, and healthy skin near or surrounding the area of pain.
  • Page 17 Neck: Attach both sets of pads to Upper Arm: Attach both the back of the neck. Do not place electrodes on either side where on carotid artery or throat. you feel pain. Upper Back: Attach both sets of electrodes to the upper back Elbow: Attach both sets of with the backbone in the center.
  • Page 18 Ankle/Foot: Wrist/Hand: Attach both sets of • For pain on the outside of the ankle or foot, attach electrodes to the hand where you electrodes above and below feel pain. the pain point. • For pain on the inside of the ankle or foot, attach 1 Knee/Joint: Attach both sets of electrode above the ankle...
  • Page 19: Treatment

    Connect the lead pins to the connectors on the electrodes. Then, place the electrodes on your skin (with the TENS unit turned OFF). Each wire has 2 leads with pin-inserted connectors. Make sure the metal on the pins is not exposed.
  • Page 20 • Intensity can be adjusted independently for Press again to resume. A and B channels. Note: If the TENS unit is inactive for 3 minutes, it • Press repeatedly on the left side and will turn off automatically. right side to raise or lower intensity for...
  • Page 21: Maintenance

    Plug the micro USB cable into a DC 5V adapter is more than 300 recharge/rundown cycles. and plug into an outlet. You can also plug the Whenever the TENS unit is not used for a long cable into a powered USB outlet. period of time, recharge the battery monthly.
  • Page 22 • Do not let water get into the TENS unit. Allow the adhesive to air dry completely. • The TENS unit and the accessories do not require sterilization.
  • Page 23 • Do not leave the TENS unit exposed to any or burns. chemical solvent, lint, or dust. • When not in use for a long period of time,...
  • Page 24: Troubleshooting

    The TENS unit won’t turn Make sure the TENS unit is charged. Intensity is too low. Raise the intensity (see Using the TENS Unit, page 16). Electrical stimulation is Electrode pads may be dried out or dirty. Wash or replace with new pads.
  • Page 25 The electrodes may be damaged, dirty, or may not be attached to the skin properly. Make sure they are clean or replace with new electrodes if necessary. You may have sensitive skin. Turn off the TENS unit and stop using immediately.
  • Page 26 Troubleshooting (cont.) Problem Possible Solution The electrodes may have come off. Turn off the TENS unit, then reattach the electrodes and continue the treatment. Output stops during Make sure the lead plug is inserted into the correct output socket. treatment.
  • Page 27: Glossary Of Symbols

    Glossary of Symbols Electrical devices are recyclable material and The first number 2: Protected against solid foreign IP22 should not be disposed of with household objects of 12.55 mm and greater. waste after their useful life. Help us protect the environment and save resources by taking this The second number 2: Protected against vertically device to the appropriate collection point.
  • Page 28 IMPORTANT INFORMATION REGARDING ELECTROMAGNETIC COMPATIBILITY (EMC) • Use of accessories other than those specified or provided by the manufacturer of this equipment could result in increased electromagnetic emissions or decreased electromagnetic immunity of this equipment and result in improper operation. •...
  • Page 29 • When the operating environment is relatively dry, strong electromagnetic interference usually occurs. At this time, this device may be affected as follows: — The device stops output — The device turns off — The device restarts The above will not affect the basic safety and essential performance of the device, and the user can use it according to the instructions.
  • Page 30 Table 1 Declaration - Electromagnetic Emission The device is intended for use in the electromagnetic environment specified below. The customer or the user of device should assure that it is used in such an environment. Emissions Test Compliance Electromagnetic Environment - Guidance The device uses RF energy only for its internal function RF emissions Group 1...
  • Page 31 Table 2 Declaration - Electromagnetic Immunity The device is intended for use in the electromagnetic environment specified below. The customer or the user of device should assure that it is used in such an environment. Electromagnetic Environment - Immunity Test IEC 60601 Test Level Compliance Level Guidance...
  • Page 32 Table 2 (cont.) 0% UT; 0% UT; 0.5 cycle At 0°, 0.5 cycle At 0°, 45°, Mains power quality should be that 45°, 90°, 135°, 180°, 90°, 135°, 180°, 225°, of a typical commercial or hospital Voltage dips, short 225°, 270° and 315° 270°...
  • Page 33 Table 3 Declaration - Electromagnetic Immunity The device is intended for use in the electromagnetic environment specified below. The customer or the user of the device should assure that it is used in such an environment. Immunity Test IEC 60601 Test Level Compliance Level Electromagnetic Environment - Guidance Portable and mobile RF communications...
  • Page 34 Table 3 (cont.) Interference may occur in the vicinity of equipment marked with the following symbol: Note 1: At 80 MHz and 800 MHz, the higher frequency range applies. Note 2: These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reflection from structures, objects and people.
  • Page 35 Table 4 Recommended Separation Distances Between Portable and Mobile RF Communications Equipment and Device The device is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled. The customer or the user of device can help prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF communications equipment (transmitters) and device, as recommended below, according to the maximum output power of the communications equipment.
  • Page 36 Table 4 (cont.) For transmitters rated at a maximum output power not listed above, the recommended separation distance d in meters (m) can be estimated using the equation applicable to the frequency of the transmitter, where P is the maximum output power rating of the transmitter in watts (W) according to the transmitter manufacturer.
  • Page 37: Warranty Information

    Some states do not allow this exclusion or Etekcity Corporation warrants all products to be of the highest quality in limitation of incidental or consequential losses so the foregoing disclaimer material, craftsmanship, and service, effective from the date of purchase may not apply to you.
  • Page 38 Warranty Information (cont.) Additional 1-Year Warranty You can extend your 1-year warranty by an additional year. Log onto www.etekcity.com/warranty to register your new product for the extended warranty. Please fill out all required fields and include your order ID, place of purchase, and purchase date, if applicable.
  • Page 39: Customer Support

    Customer Support Team. Your satisfaction is our goal! Customer Support Support Hours Monday—Friday Distributed by Etekcity Corporation 9:00 am —5:00 pm PST/PDT 1202 N. Miller St., Suite A Anaheim, CA 92806 *Please have your invoice and order ID ready before contacting Customer Support.
  • Page 40 Notes...
  • Page 41 Notes...
  • Page 42 Notes...
  • Page 43 Connect with us @Etekcity...
  • Page 44 Building on better living. V1.0_20190621...

This manual is also suitable for:

Etu-134

Table of Contents