Cisco MGX 8230 Installation And Configuration Manual page 190

Cisco systems edge concentrator installation and configuration guide
Table of Contents

Advertisement

ATM Universal Service Module (AUSM)
Variable
Chan_Num
ABRType
mcr
pcr
icr
rif
rdf
nrm
trm
tbe
frtt
adtf
cdf
Step 5
If necessary, change the queue depths by using cnfchanq.
cnfchanq <port.vpi.vci> <discard_option> <vc_q_depth> <clp_thresh_high> <clp_thresh_low |
epd_threshold> <efci_thresh>
Cisco MGX 8230 Edge Concentrator Installation and Configuration
6-22
Description
Value range
ABRType
1 (Switch Behavior) and 2 (Source Destination
Behavior).
Minimum Rate Valid value range from 10 to 38328 (includes
RM cell and Data cell bandwidth).
Peak Rate
Valid value range from 10 to 38328 (includes
RM cell and Data cell bandwidth).
Initial Cell
Valid value range from 10 to 38328 (includes
Rate
RM cell and Data cell bandwidth).
Rate Increase
Valid range from 1 to 32768 (power of 2)
Factor
Rate Decrease
Valid range from 1 to 32768 (power of 2)
Factor
Inrate Cell
Valid value range from 2 to 256 (power of 2).
Count
Time limit for
Valid value range from 3 to 255 msec.
Frm
Transient Buf
Valid value range from 0 to 16777215 cells.
Exposure
Fixed Round
Valid value range from 0 to 16700 msec.
Trip Time
ACR Decrease
Valid value range from 10 to 10230 msec.
Time Factor
Cutoff
Valid value range from 0 to 64 (power of 2).
Decrease
Factor
Chapter 6
Card and Service Configuration
Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001
Default value
1 (Switch
Behavior)
Derived from
PCR(0+1)
Derived from
PCR (0+1)
Derived from
PCR (0+1)
64
16
64
255 msec.
16777215 cells
0 msec.
500msec.
16

Advertisement

Table of Contents
loading

Table of Contents