Stainless Steel Smoke Deflector Installation

The stainless smoke deflector is located in the upper front area of the firebox. The deflector is held in place with 2 bolts
Prior to the first fire, ensure deflector is seated properly and secured with 2 hand tightened bolts which are accessible from behind the smoke deflector.
Smoke deflector
Smoke deflector is installed through the door opening in location shown in Diagram
To replace the deflector, loosen off both bolts and slide deflector downward, push deflector to the back wall of the unit and manoeuver out.
Install new deflector and hand tighten bolts.
Ensure positive location of the deflector prior to hand tightening.
WARNING: Operation of the unit with out proper installation of smoke deflector will void warranty.
Ensure deflector is seated so bolts are seated
at the bottom of the slot before tightening.
Smoke deflector installed with 2 bolts.
Note: This is a cutaway view from the back of
the unit
Regency CI1150 Wood Cast Insert
installation
|
17