INSTALLATION

INSTALLING TRACK MOUNT

(CT, ST AND RT)
NOTICE
Hatco DL lamp warmers are built to fit HALO
brand L651, L652 and L653 Power Trac, track
lighting systems only. Do not attempt to use on
any other track lighting system.
CAUTION
For safe and proper operation the maximum
capacity of Power-Trac is 20A per circuit. Check
the fuses and circuits carefully before installing.
20A maximum includes all lights and appliances
connected to the circuit. 120 volt only, maximum
1920 watts per any length track.
The Trac system is to be supplied by a single branch
circuit 120V, 60 Hz, 20A.
NOTE: Maximum seven 250 watt lamp units or five
375 watt lamp units per each 20 amp Track Bar
circuit. Installer is responsible for properly sizing the
supply circuit with the lamp load.
Hatco provides track kits in three different lengths:
• L651 - 4 ft. (1219 mm)
• L651 - 8 ft. (2438 mm)
• 652 - 12 ft. (3658 mm) (L653).
When installing or using this Trac system, the
following basic safety precautions should always
be followed:
Read all of these installation instructions before
installing the Trac system.
Save these instructions and refer to them when
additions to or changes in the Trac configuration
are made.
Do not install this Trac in damp or wet locations.
Do not install any part of a Trac system less than
5 feet (1524 mm) above the floor.
Do not install any fixture assembly closer than
1" (25 mm) along the sides from any curtain or
similar combustible material.
Disconnect electrical power before adding
to or changing the configuration of the Trac.
Form No. DHLM-1207
Do not attempt to energize anything other than
Trac lighting fixtures on the Trac. To reduce the
risk of fire and electric shock, do not attempt to
connect
power
appliances, etc. to the Trac.
For safe and proper operation do not use
Trac system units with a power supply cord
or convenience receptacle adapter.
To reduce the risk of fire and electric shock
when installing Trac systems, use only fixture
assemblies marked for use with Halo Trac, and
Trac Fittings marked for use with L650 Series
Trac.
The mounting clips, screws or stems are to be
mounted in pre-drilled holes as follows:
2 foot (610 mm) Trac-two places, one at each
end of Trac.
4 foot (1219 mm) Trac-two places, one at each
end of Trac.
8 foot (2438 mm) Trac-three places, one in the
center and each end of the Trac.
12 foot (3658 mm) Trac-four places, one at
each end of Trac and four feet from each end.
If Trac requires field cutting, refer to Field Cutting
Trac to Special Lengths. If Trac does not require
field cutting, proceed to Installing the Trac.