Accessories; Troubleshooting Guide - Hatco DL-400 Installation And Operating Manual

Decorative heat lamps dl series
Hide thumbs Also See for DL-400:
Table of Contents

Advertisement

TRACK BAR MOUNT
Track Bar Mount specify 4' (1219 mm), 8'
(2438 mm), or 12' (3658 mm) track length and color
option of black or white. Track bar can be cut down
in the field.
WARNING
To avoid any injury or damage the Decorative
Heat Lamps must only be serviced by qualified
personnel.
SYMPTOM
Unit is not working at all.
Unit is turned "ON" but there
is no light.
Heat is inadequate.
PROBABLE CAUSE
Unit not turned on.
ON/OFF switch is not
functioning.
No power to unit.
Switch is defective.
Heating bulb is defective.
Unit mounted too high above
target area.
Excessive air movement
around Decorative Heat
Lamp target area.
Incorrect power supply (low).
13
NOTE: Maximum seven 250 watt lamp units or five
375 watt lamp units per each 20 amp track bar
circuit. Installer is responsible for properly sizing the
supply circuit with the lamp load.

TROUBLESHOOTING GUIDE

WARNING
To avoid any injury or damage to the Decorative
Heat Lamps turn the power OFF at the
disconnect switch/circuit breaker and allow to
cool before performing any maintenance.
CORRECTIVE ACTION
Place ON/OFF switch, if equipped, in the
ON position.
Contact Authorized Service Agent for
repair.
Check circuit breaker and reset as
necessary.
Contact Authorized Service Agent for
repair.
Replace heating bulb if defective.
Lower unit, putting effective heat closer
to target.
Restrict or redirect air movement (ie. - air
conditioning duct or exhaust fan) away
from unit.
Check power supply to unit, making sure
it matches rating on the unit. If power
supply is incorrect, change to match
rating on unit.

ACCESSORIES

Form No. DHLM-1207

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dl-500Dl-700Dl-725Dl-750Dl-760Dl-775 ... Show all