Hatco GR Installation And Operating Manual

Hatco GR Installation And Operating Manual

Glo-ray series infrared strip heaters

Advertisement

hatcocorp.com
Register Online!
(see page 2)
S'inscrire en ligne!
(voir page 20)
Rampes Chauffantes à Infrarouge
GR, GRH, GRL, GRHL, GRA, GRAH, GRAL,
GRAHL, GRN, GRNH Series/Série
Installation and Operating Manual
Manuel d'installation et d'utilisation
WARNING
Do not operate this equipment unless you
have read and understood the contents of
this manual! Failure to follow the
instructions contained in this manual may
result in serious injury or death. This
manual
contains
important
information concerning the maintenance,
use, and operation of this product. If
you're unable to understand the contents
of this manual, please bring it to the
attention of your supervisor. Keep this
manual in a safe location for future
reference.
English = p 2
GLO-RAY
Infrared Strip Heaters
P/N 07.04.413.00
ADVERTENCIA
No opere este equipo al menos que haya
leído y comprendido el contenido de este
manual! Cualquier falla en el seguimiento
de las instrucciones contenidas en este
manual puede resultar en un serio lesión
safety
o
muerte.
Este
importante información sobre seguridad
concerniente al mantenimiento, uso y
operación de este producto. Si usted no
puede entender el contenido de este
manual
por
supervisor. Almacenar este manual en
una localización segura para la referencia
futura.
®
manual
contiene
favor
pregunte
a
su
AVERTISSEMENT
Ne pas utiliser cet équipement sans avoir
lu et compris le contenu de ce manuel !
Le
non-respect
des
contenues dans ce manuel peut entraîner
de graves blessures ou la mort. Ce
manuel
contient
des
importantes
concernant
l'utilisation et le fonctionnement de ce
produit. Si vous ne comprenez pas le
contenu de ce manuel, veuillez le signaler
à votre supérieur. Conservez ce manuel
dans un endroit sûr pour pouvoir vous y
référer plus tard.
Français = p 20
© 2015 Hatco Corporation
instructions
informations
l'entretien,

Advertisement

Table of Contents
loading

Summary of Contents for Hatco GR

  • Page 1 (see page 2) ® S'inscrire en ligne! (voir page 20) Infrared Strip Heaters Rampes Chauffantes à Infrarouge GR, GRH, GRL, GRHL, GRA, GRAH, GRAL, GRAHL, GRN, GRNH Series/Série Installation and Operating Manual Manuel d'installation et d'utilisation P/N 07.04.413.00 WARNING AVERTISSEMENT...
  • Page 2: Table Of Contents

    Central Standard Time (CST) purchase date of your strip heater in the spaces below (specification label located on the underside of the unit). Please (Summer Hours: June to September— have this information available when calling Hatco for service 8:00 to 5:00 CST monday–Thursday assistance.
  • Page 3: Important Safety Information

    To prevent premature failure of components due to excessive heat, remote mounted control switches must be installed outside a. Do not install standard wattage strip heaters (GR, GRA, the strip heater heat zone. GRN, GRL, and GRAL Series) less than 10″ (254 mm) above combustible surfaces.
  • Page 4: Model Description

    Optional infinite control switches, remote control enclosures, incandescent lighting, and sneeze guards are available also. GR-xx, GRH-xx, GRL-xx, and GRHL-xx Models GRaHL-48 model Stainless steel models are available with or without...
  • Page 5: Specifications

    NOTE: Cord and plug configurations are not available for units with adjustable tubular stands or non-adjustable tubular Plug Configuration stands. NOTE: Receptacle not supplied by Hatco. NOTE: Refer to the wiring diagram supplied with the unit and WARNING specification label attached to the unit for specific ELECTRIC SHOCK HAzARD: Plug unit into a properly electrical information.
  • Page 6: Installation

    6″ (152 mm) spacer. maintained, discoloration or combustion could occur. NOTE: Dual units are available with aluminum housings only. a. Do not install standard wattage strip heaters (GR, GRA, GRN, GRL, and GRAL Series) less than 10″ (254 mm) above combustible surfaces.
  • Page 7: Recommended Mounting Heights

    (203–279 mm) (279–356 mm) combustible surroundings. Shelf 12″ (305 mm) Recommended Element Height for the GR, GRa, GRL, GRH, GRHL, GRN, GRaH, GRaL, GRNH, and GRaHL models in all lengths (excluding dual models). 15″ (381 mm) Standard Wattage High Wattage Height...
  • Page 8: Minimum Clearance Requirements For Non-Combustible Surroundings

    INSTALLATION English Minimum Clearance Requirements for Non-Combustible Surroundings Corded Units with Built-In Switches Models (B)* Shelf GRa and 10″ 3″ GRaL (254 mm) (76 mm) 11″ 3″ GRaH and GRaHL (279 mm) (76 mm) Hardwired Units with Built-In Switches Models (B)* Counter GRa and...
  • Page 9: Installing Portable Units

    INSTALLATION English Installing Portable Units T-Leg Stand Mounting T-Leg stands are available in the following heights: Single strip heaters under 6′ (1829 mm) long can be mounted on C-Leg or T-Leg stands for portable use. Portable units are • Standard wattage units = 10″ (254 mm) available in 120 V only and are required to have a power cord •...
  • Page 10: Installing Chain Suspended Units

    NOTE: Tubular stands are not field retrofittable. NOTE: The strength of the chain supplied by Hatco is sufficient NOTE: If wiring is to be concealed, a 1″ (25 mm) diameter hole to hold the weight of the unit securely only when must be provided in the mounting surface under the mounted properly.
  • Page 11 5. Fasten the angle brackets to the underside of the shelf mounting a strip heater with adjustable angle brackets using appropriate fasteners (not supplied by Hatco). permanently attaches the unit to the underside of a shelf. Units NOTE: Two pairs of brackets will be needed for dual units.
  • Page 12: Electrical Information

    Install supply wire and connectors suitable for at least 194°F Use the following procedure to install adjustable angle brackets (90°C). on each end of stainless steel housing models (GR and • Use a minimum of No. 14 aWG copper wire for individual GRH models).
  • Page 13 English Remote Control Enclosures Remote Mounted Control Switches Hatco remote control enclosures include switches, wire leads, Optional remote mounted control switches include ON/OFF and/or indicator lights and are shipped ready for installation. toggle switches and infinite control switches. These switches...
  • Page 14: Operation

    OPERATION English General Glo-Ray Infrared Strip Heaters are designed for ease of ® operation. Use the following information and procedures to operate the unit. WARNING Read all safety messages in the IMPORTANT SAFETY INFORMATION section before operating this equipment. CAUTION BURN HAzARD: Some exterior surfaces on unit will get hot.
  • Page 15: Maintenance

    2. Unscrew the light bulb from the unit and replace it with a This unit has no “user-serviceable” parts. If service is new, specially-coated incandescent or optional halogen required on this unit, contact an Authorized Hatco Service bulb. Agent or contact the Hatco Service Department at 800-558-0607 or 414-671-6350;...
  • Page 16: Troubleshooting Guide

    Switches used are not Hatco supplied. Genuine Hatco Parts are specified to operate safely and properly in the environment in which they are used. Contact authorized Service agent or Hatco to replace switches with Genuine Hatco Replacement Parts.
  • Page 17 OPTIONS AND ACCESSORIES English Remote Control Enclosures — RMB Series 3. Remove the wiring access cover on bottom of the control enclosure by removing screws and sliding cover off. RmB Series remote control enclosures are available in various configurations for use with strip heaters. Remote control 4.
  • Page 18 NOTICE The infinite switch must be installed using the terminals and wires supplied with the switch. Failure to use the supplied Genuine Hatco Replacement Parts will void all warranties and may damage the equipment. Dimensions — RmB2s RMB2 Series Cutout Dimensions...
  • Page 19: Limited Warranty

    Product’s purchase date by registering the Product bulbs, fluorescent lights, heat lamp bulbs, coated halogen light with Hatco or by other means satisfactory to Hatco in its sole bulbs, halogen heat lamp bulbs, xenon light bulbs, LED light discretion.