INSTALLATION

Mounting Height Requirements

4"–6"
(102–152 mm)
Standard Wattage
Height
8"–11"
(203–279 mm)
12" (305 mm)
Figure 10. Recommended Element Height for the
GR, GRA, GRH, GRN, GRAH, GRAL, GRNH, and
GRAHL models in all lengths (excluding dual models).
15" (381 mm)
Standard Wattage
Height
10"–14"
(254–356 mm)
21" (533 mm)
Figure 11. Recommended Element Height for the
GRA-D, GRAH-D, GRAL-D & GRAHL-D dual models
with a 3" (76 mm) spacer in all lengths.
18" (457 mm)
Standard Wattage
Height
10"–14"
(254–356 mm)
24" (610 mm)
Figure 12. Recommended Element Height for the
GRA-D, GRAH-D, GRAL-D & GRAHL-D dual models
with a 6" (152 mm) spacer in all lengths.
All manuals and user guides at all-guides.com
Add 3" for
units with lights.
High Wattage
Height
11"–14"
(279–356 mm)
High Wattage
Height
14"–18"
(356–457 mm)
High Wattage
Height
14"–18"
(356–457 mm)
12

Assembly

Glo-Ray Strip Heaters are shipped with most
components pre-assembled. Dual units are
available with a required 3" (76 mm) or 6" (152 mm)
spacer pre-assembled at the factory.
Optional sneeze guards, mounting equipment, and
remote control enclosures must be installed on
location.
Portable Surface Mounting
Single strip heater units can be mounted on C-Leg
or T-Leg stands for portable use. Portable units are
available in 120V only and are required to have a
power cord and plug connection.
NOTE: C-Legs and T-Legs are not to be used with
dual strip heater units.
C-Leg Stand Mounting
Two types of C-Legs are available.
• CL-Low = 10" (254 mm) height, for standard
wattage strip heaters up to 5'
(1524 mm) in width only.
• CL-High = 13-1/2" (343 mm) height, for high
wattage strip heaters up to 5'
(1524 mm) in width only.
CL-Low
11-1/8"
(283 mm)
Figure 13. C-Leg Footprint Dimensions
Perform the following procedure to install a C-Leg
stand on each end of the unit.
1. Position the unit upside-down on a flat surface.
2. Install sneeze guard(s), if required (refer to the
"Sneeze Guard Installation" procedure in this
section).
3. Remove the two screws and hanger tabs from
the end of the unit.
4. Remove the one end plate screw that aligns
with the lowest mounting hole on the C-Leg (see
Figure 14).
5. Align the three mounting holes on the C-Leg
with the three holes on the unit. Secure the leg
to the unit with the three screws removed in the
previous steps.
CL-High
12-1/4"
(311 mm)
Form No. GRM-0508