Baud Switches - Oki Dr.63514 User Manual

In-circuit emulator
Table of Contents

Advertisement

2.16 BAUD Switches

The BAUD switches at the rear of the emulator offer a choice of eight baud rates from 4800 to 115200
bps.
The baud rate settings are as follow.
baud rate
4,800bps
9,600bps
19,200bps
38,400bps
51,200bps
57,600bps
76,800bps
115,200bps
All other serial interface parameters are fixed: 8 bits, no parity, 1 stop bit, XON/XOFF flow control.
_______________________________________________________________________________________________________________
n Note 1 n
The IBM PC/AT and compatibles do not support the 51,200bps and 76,800bps speeds. When
turning on or resetting the Dr.63514, if an initialization message is not produced on the
dedicated debugger's screen or a communication error occurs, lower both the Dr.63514 baud
rate setting and the dedicated debugger's speed parameter.
_______________________________________________________________________________________________________________________________
ON
OFF
Figure 2-22 BAUD Switch
BAUD
38400
switch
OFF
OFF
OFF
ON
ON
ON
ON
OFF
ON
OFF
19200
9600
OFF
OFF
OFF
ON
ON
OFF
OFF
OFF
ON
ON
ON
OFF
OFF
ON
ON
ON
Chapter 2. Functions
4800
ON
OFF
OFF
OFF
OFF
ON
ON
ON
2-45

Advertisement

Table of Contents
loading