2.12 Backup Switching

The ML63512/514 includes a built-in backup circuit that doubles the power-supply voltage. The backup
circuit is used when the positive power-supply voltage (VDD) falls below 1.8 V. The Dr.63514 in-circuit
emulator includes an ML63514 to implement the level detector and comparator functions. The positive
power-supply voltage (VDD) in this ML63514 depends on the setting of the VDD.SEL switch, and has
the same external input voltage range as the ML63512/514, namely 0.9 to 5.5 V. The backup circuit
on/off setting for the ML63514 used in the Dr.63514 in-circuit emulator must be set appropriately as
well. The BACKUP switch sets the backup state of the ML63514 used in the Dr.63514 in-circuit
emulator.
operating condition for the operating voltage
1.5 V internally or 0.9 to 1.8 V externally
1.8 to 5.5 V externally
_______________________________________________________________________________________________________________
n Note 1 n
This BACKUP switch is completely unrelated to the backup function of the ML63512/514 being
evaluated. The ML63512/514 backup function is implemented using only the BUPCON register
in the Dr.63514 in-circuit emulator.
_______________________________________________________________________________________________________________________________
Caution
ON
OFF
Figure 2-19 Backup Switch
The BACKUP switch must be set to the operating
voltage used. If the switch is set to the wrong position,
the ML63514 used in the Dr.63514 in-circuit emulator
may be destroyed.
Chapter 2. Functions
Backup Switch
ON
OFF
ON
OFF
2-41