Product Information
2
Product Information
2.1
Declaration of conformity
The design and operating characteristics of this product comply with the
European and national requirements.
The CE marking declares that the product complies with all the
applicable EU legislation, which is stipulated by attaching this
marking.
The complete text of the Declaration of Conformity is available on the
Internet: worcester-bosch.co.uk.
2.2
Simplified EU Declaration of Conformity regarding
radio equipment
Bosch Thermotechnik GmbH hereby declares, that the Climate Class
6000i/8000i product described in these instructions complies with the
Directive 2014/53/EU.
The complete text of the EU Declaration of Conformity is available on the
Internet: worcester-bosch.co.uk.
2.3
Scope of delivery
Key to Fig. 1:
[1]
Outdoor unit (filled with refrigerant)
[2]
Indoor unit (filled with nitrogen)
[3]
Mounting Plate
[4]
Mirror sheet metal (only for coloured product types
1)
CLC8001i... T/S/R)
[5]
Terminal cover with screw
[6]
Remote control with batteries
[7]
Set of printed documents for product documentation
[8]
Fixing materials (7 long screws, 1 special screw for fixing the
remote control and 8 wall plugs)
[9]
Sheet metal (for fixing the cable in the strain relief)
[10] Drainage connection and drainage tray
(only for product types CLC8001i...)
[11] Drainage connection (only for product types CLC6001i...)
2.4
Product dimensions and minimum clearances
2.4.1
Indoor unit and outdoor unit
Fig. 2
[1]
Wall plug (scope of delivery)
[2]
Special screw (scope of delivery)
A
CLC8001i... model
B
CLC6001i... model
1) Fastening the mirror metal sheets Fig. 10
34
2.4.2
Refrigerant lines
Key to Fig. 3:
[1]
Pipe on gas side
[2]
Pipe on liquid side
[3]
Siphon-shaped elbow as oil separator
If the outdoor unit is positioned higher than the indoor unit, install a
siphon-shaped elbow on the gas side after no more than 6 m and every
6 m thereafter ( Fig. 3, [1]).
▶ Observe maximum pipe length and maximum difference in height
between indoor unit and outdoor unit.
Maximum pipe
length
All types
1) Gas side or liquid side
2) Measured from bottom edge to bottom edge.
Table 2 Pipe length and difference in height
Unit type
Liquid side [mm]
All types
6.35 (1/4")
Table 3 Pipe diameter depending on unit type
Pipe diameter [mm]
6.35 (1/4")
9.53 (3/8")
Table 4 Alternative pipe diameter
Specification of the pipes
Min. piping length
Additional refrigerant if the pipe length
exceeds 7.5 m (liquid side)
Pipe thickness with 6.35 mm to 12.7 mm
pipe diameter
Thickness of insulation against heat
Material of insulation against heat
1) Prefilled for maximum pipe length of 15 m.
Table 5
Climate Class 6000i/8000i – 6721831489 (2021/02)
Maximum height
1)
2)
[m]
difference
[m]
≤ 15
≤ 10
Pipe size
Gas side [mm]
9.53 (3/8")
Alternative pipe diameter [mm]
6
10
3 m
CLC6001i...: 15 g/m
1)
CLC8001i...: 0 g/m
≥ 0.8 mm
≥ 6 mm
Polyethylene foam