Product Information

2.1

Scope of delivery

Key to Fig. 1:
[1]
Outdoor unit (filled with refrigerant)
[2]
Indoor unit (filled with nitrogen)
[3]
Cold catalyst filter and bio filter
[4]
Drainage elbow with gasket
(for outdoor unit with floor or wall mounting bracket)
[5]
Remote control with batteries
[6]
Remote control holder with fixing screw
[7]
Fixing materials (5 screws and 5 wall plugs)
[8]
Set of printed documents for product documentation
[9]
4 anti-vibration couplings for the outdoor unit
2.2

Product dimensions and minimum clearances

2.2.1

Indoor unit and outdoor unit

Figures 2 to 4.
2.2.2

Refrigerant pipes

Key to Fig. 5:
[1]
Gas-side pipe
[2]
Liquid-side pipe
[3]
Siphon-shaped elbow as oil separator
If the outdoor unit is positioned higher than the indoor unit, install a
siphon-shaped elbow on the gas side after no more than 6 m and every
6 m thereafter ( Fig. 5, [1]).
▶ Observe maximum pipe length and maximum difference in height
between indoor unit and outdoor unit.
Maximum pipe
length
CLL5000i 26
CLL5000i 35
CLL5000i 53
CLL5000i 65
1) Gas side or liquid side
2) Measured from bottom edge to bottom edge.
Table 2 Pipe length and difference in height
Unit type
Liquid side [mm]
CLL5000i 26
6.35 (1/4")
CLL5000i 35
6.35 (1/4")
CLL5000i 53
6.35 (1/4")
CLL5000i 65
9.53 (3/8")
Table 3 Pipe diameter depending on appliance type
Pipe diameter [mm]
6.35 (1/4")
9.53 (3/8")
12.7 (1/2")
15.9 (5/8")
Table 4 Alternative pipe diameter
Climate Line 5000i – 6721831693 (2022/05)
Maximum difference
1)
2)
[m]
in height
[m]
≤ 25
≤ 10
≤ 25
≤ 10
≤ 30
≤ 20
≤ 30
≤ 20
Pipe size
Gas side [mm]
9.53 (3/8")
12.7 (1/2")
12.7 (1/2")
15.9 (5/8")
Alternative pipe diameter [mm]
6
10
12
16
Specification of the pipes
Min. piping length
Additional refrigerant if the pipe length
exceeds 5 m (liquid side)
Pipe thickness with 6.35 mm to 12.7 mm
pipe diameter
Pipe thickness with 15.9 mm pipe
diameter
Thickness of heat insulation
Material of heat insulation
Table 5
3

Installation

3.1

Before installation

CAUTION
Risk of injury from sharp edges!
▶ Wear protective gloves during installation.
CAUTION
Danger of burns!
During operation the pipes become hot.
▶ Make sure, that the pipes cooled down before touching them.
▶ Check the scope of delivery for damage.
▶ Check whether a hissing sound due to negative pressure can be
detected when opening the pipes of the indoor unit.
3.2

Requirements for installation site

▶ Observe minimum clearances ( Figs. 2 to 4).
Indoor Unit
▶ The installation location must not be higher than 2000 m above sea
level.
▶ Keep the air inlet and air outlet clear of any obstacles to allow the air
to circulate freely. Otherwise poor performance and higher noise
levels may occur.
▶ Keep TV, radio and and similar appliances at least 1 m away from the
unit and the remote control.
▶ Mount the indoor unit on a wall that absorbs vibrations.
Outdoor unit
▶ The outdoor unit must not be exposed to machine oil vapour, hot
spring vapour, sulphur gas, etc.
▶ Do not install the outdoor unit directly next to water or where it is
exposed to sea air.
▶ The outdoor unit must always be kept free of snow.
▶ There must be no disruption caused by extract air or operating noise.
▶ Air should be able to circulate freely around the outdoor unit, but the
appliance must not be exposed to strong wind.
▶ Condensate that forms during operation must be able to drain off
easily. Lay a drain hose if required. In cold regions, installation of a
drain hose is not advisable as it could freeze.
▶ Place the outdoor unit on a stable base.
Product Information
3 m
With Ø 6.35 mm (1/4"):
15 g/m
With Ø 9.53 mm (3/8"):
30 g/m
≥ 0.8 mm
≥ 1.0 mm
≥ 6 mm
Polyethylene foam
21