Troubleshooting The Pos Uplink Card Installation; Alarm Processing - Cisco CISCO10720 Installation And Configuration Manual

Internet router uplink cards installation and configuration
Table of Contents

Advertisement

Chapter 5
Troubleshooting the Uplink Cards
Static information
Transceiver status information
Diagnostics calibration is external
Temperature 38 (+/-3 Celsius)
No Active Alarms
No Active Warnings
Alarm Thresholds:
Temperature
Voltage
TX bias
TX power
RX power
Warning Thresholds:
Temperature
Voltage
TX bias
TX power
RX power

Troubleshooting the POS Uplink Card Installation

This section provides information for troubleshooting the POS/DPT uplink card installation.

Alarm Processing

The following system alarms are monitored by the POS uplink card and reported to the console port:
78-13113-06 B0
ID: SFP transceiver
Extended ID: 4
Connector: LC
SONET compliance: OC48SR
Gigabit Ethernet compliance: unspecified
Fibre Channel link length: unspecified
Fibre Channel transmitter technology: unspecified
Fibre Channel transmission media: unspecified
Fibre Channel speed: unspecified
Encoding: reserved
Bit Rate: 2500 Mbps
Single mode fiber supported length: 2 km
Upper bit rate limit: unspecified
Lower bit rate limit: unspecified
Date code (yyyy/mm/dd): 2004/04/21
Vendor PN: SCP6828-C5-BNE
Vendor revision number: D
Vendor serial number: ECL0817001M
Voltage in transceiver 3230800 uV (+/- 10 mV)
TX bias 8724 uA (+/- 100uA)
TX power 285600 nW / -5 dBm (+/- 3dBm)
RX power 309900 nW / -5 dBm (+/- 3dBm)
high
96 C
4000000 uV
70000 uA
1000000 nW / 0
1008300 nW / 0
high
91 C
3600000 uV
60000 uA
630900 nW / -2
1008300 nW / 0
Loss-of-Signal (LOS)
Loss-of-Frame (LOF)
Line Alarm Indication Signal (LAIS)
Line Remote Defect Indication (RDI)
Troubleshooting the POS Uplink Card Installation
low
-44 C
0 uV
0 uA
dBm
50100 nW / -13 dBm
dBm
unspecified
low
- 9 C
3000000 uV
0 uA
dBm
79400 nW / -11 dBm
dBm
unspecified
Book Title
5-15

Advertisement

Table of Contents
loading

This manual is also suitable for:

10720

Table of Contents