Tyco DV-5A Red-E Cabinet Quick Start Manual page 4

Red-e cabinet integrated deluge fire protection package
Hide thumbs Also See for DV-5A Red-E Cabinet:

Advertisement

TFP1301
Page 4 of 8
Description
Automatic Water Control Valve and Deluge Trim
Wet Pilot Actuation
Dry Pilot Actuation
Electric Actuation
Remote-Resetting
Remote-Resetting, Pressure-Reducing
System Shut-Off Valve, 1 1/2 to 2 in. (DN40 to DN50)
System Shut-Off Valve, 3 to 8 in. (DN75 to DN200)
Pressure Alarm Switch, POTTER
Pressure Alarm Switch, POTTER
Control Panel, Potter Electric Signal
Air Maintenance Device
2
, Regulator Type
Air Maintenance Device
3
, Switch Type
Nitrogen Maintenance Device
Notes
1. The Model PFC-4410RC is standard. The Red-E Cabinet may be ordered without an integral control panel. Red-E Cabinets featuring remote-resetting and remote-resetting,
pressure-reducing system types are not offered with a control panel.
2. The Model AMD-1 Air Maintenance Device, in addition to an auxiliary air tank, is utilized as standard equipment for dry pilot actuation having a compressor that delivers air at
5.5 ft³/min (0.16 m³/min) or higher. In the case of dry pilot actuation, the automatic air supply is utilized for the air pressure required for the dry pilot lines.
An OL12516AC (1/6 HP) air compressor is provided as standard for maintaining the air pressure in the auxiliary air tank.
3. The Model AMD-2 Air Maintenance Device and Model AMD-3 Nitrogen Maintenance Device, as well as the Model AMD-1 Air Maintenance Device, are offered as options when
the Red-E Cabinet for Dry Pilot Actuation is ordered without a built-in automatic air supply (for example, air compressor).
4. Approvals under the name of LANSDALE VALVE & MANUFACTURING.
5. Approvals under the name of POTTER.
* TDS - Technical Data Sheet
Horsepower
Model
Rating
Number
OLR12016AC
OLR25033AC
OLR40050AC
OLR43075AC
OLR615100AC
2
OLR915150AC
2
OLR1225200AC
2
Notes
1. Dry Pilot Actuation is provided as standard with a Model OLR12016AC Air Compressor.
2. For 6 in. (DN150) and 8 in. (DN200) cabinets only.
1
3
PRINCIPAL COMPONENTS
TECHNICAL DATA SHEETS AND LABORATORY APPROVALS
Voltage
(hp)
115/208-230 VAC
1/6
60 Hz
115/208-230 VAC
1/3
60 Hz
115/208-230 VAC
1/2
60 Hz
115/208-230 VAC
3/4
60 Hz
115/208-230 VAC
1
60 Hz
115/208-230 VAC
1 1/2
60 Hz
208-230 VAC
2
60 Hz
60 HZ AIR COMPRESSOR SELECTION CRITERIA
FOR DELUGE DRY SYSTEM ARRANGEMENTS
BASED ON SYSTEM TYPE AND VOLUME
Model
TDS
TFP1311
TFP1316
DV-5
A
TFP1321
TFP1325
TFP1326
POWERBALL
BFV-300
TFP1511
PS10-2A
PS40-2A
PFC-4410RC
AMD-1
TFP1221
AMD-2
TFP1231
AMD-3
TFP1241
TABLE A
Electric/Electric
Actuation
1
System Volume
@20 psi (1.38 bar) in 30 mins
gal (L)
240 (909)
475 (1795)
800 (3028)
930 (3520)
1430 (5410)
2320 (8780)
3040 (11500)
TABLE B
*
UL
C-UL/ULC
X
X
X
X
X
X
X
X
X
X
X
4
X
4
X
X
X
5
X
5
X
5
X
5
X
5
X
5
X
X
X
X
X
X
Electric/Pneumatic
Actuation
System Volume
@40 psi (2.76 bar) in 30 mins
gal (L)
120 (454)
250 (945)
400 (1514)
430 (1625)
615 (2325)
915 (3460)
1225 (4635)
FM
X
X
X
X
X
X
4
X
X
5
X
5
X
5
X
X
X

Advertisement

loading

This manual is also suitable for:

Olr12016acOlr25033acOlr40050acOlr43075acOlr615100ac2Olr915150ac2 ... Show all