I/O CONNECTIONS

For maximum noise immunity, I/O wiring should be
run in conduit or cables having a foil shield with an
overall braided shield. The foil shield provides 100%
shielding, while the braid provides a means of making
proper 360° shield terminations at the cable to cabinet
connection points. To make I/O connections using
shielded cable, perform the following:
1. Remove the cable grommet hardware from the
desired I/O connector housing (See Figure 7).
2. Route the desired length of I/O cable through the
connector housing and mark 1" span of cable
that passes through the connector housing to be
stripped to braid (See Figure 8).
3. Remove cable and strip marked 1" section to
cable braid.
4. Slide the cable grommet hardware onto the cable
in the order shown in Figure 7.
5. Route the cable back through the connector housing
and connect its wires to the desired I/O terminals
inside the 9060 Controller.
6. Tighten the cable grommet ensuring the grommet
spring makes 360° contact with the exposed braid
of the cable, for maximum noise immunity.
7. For maximum noise immunity, connect the braid
of the cable to earth ground at the end opposite
the Controller.
CP-17-02
9060 Classic High Voltage Controller -
CABLE
GROMMET
ANALOG I/O CABLE
1/4" (0.64cm)
1" (2.54cm)
CONNECTOR

AC INPUT CONNECTIONS

For non-conduit installations, plug the detachable AC
line cord into the receptacle on the side of the 9060
Controller. Plug the other end of the line cord into a
properly grounded AC outlet.
Figure 7: Cable Grommet
HOUSING
Figure 8: I/O Cable Stripping
INSTALLATION
INSIDE OF
CABINET
14