SERVICE INSTRUCTION
The DynaFlow fluid flow controller (Models A12233 and 77376) and RansFlow fluid flow con-
troller (Model A12410) have been revised to comply with the latest CE directives and stand-
ards. This compliance kit has been assembled to allow minor field modification of these con-
trollers to add the required hardware and documentation.
1. An input line filter is required (p/n A13226) to be wired between the input power conductors
and the internal power supply. Mounting instructions and wiring diagrams can be found below
and in the kit with the filter.
CE Compliance Kit
SERVICE INSTRUCTION
SI–13– 01
January 2013
1

Advertisement

loading

Summary of Contents for Ransburg DynaFlow A12233

  • Page 1 SERVICE INSTRUCTION SI–13– 01 January 2013 SERVICE INSTRUCTION CE Compliance Kit The DynaFlow fluid flow controller (Models A12233 and 77376) and RansFlow fluid flow con- troller (Model A12410) have been revised to comply with the latest CE directives and stand- ards.
  • Page 2 DynaFlow A12233 wiring diagram for filter installation.:...
  • Page 3 DynaFlow A77376 wiring sketch for filter installation:...
  • Page 4 RansFlow wiring diagram for filter installation: 2. The protective conductor ground label (p/n TRM-35-038) must be placed adjacent to the protective ground terminal block. Note: The RansFlow may already have this label properly placed.
  • Page 5 3. There are two electrical hazard labels (p/n A13205-00) included in the kit. One must be placed on the front of the cabinet above the lower door latch. For DynaFlow only -The other must be placed on the inside of the cabinet on the back of the touch screen computer near the line power conductors.
  • Page 6 A13224). 6. The updated Declaration of Conformity has been provided in the kit. Additional copies are available upon request by calling our Technical Support on the back page. DynaFlow A12233 and 77376 Declaration of Conformity IL-285-E • RansFlow A12410 Declaration of Conformity IL-327 •...
  • Page 7 8. The complete updated service manuals can be downloaded from the Ransburg website or is available upon request by calling our Technical Support number on the back page. Particular service manual additions / updates relate to installation instructions, wiring, grounding and...
  • Page 10 Telephone (toll free): 800-233-3366 Fax: 419-470-2233 Technical Support Representative will direct you to the appropriate telephone number for ordering Spare Parts. Form No. SI-13-01 © 2013 Ransburg. All rights reserved. Litho in U.S.A. Models and specifications subject to change without notice. 1/13...