Connection Interface; Connectors - Ransburg 9060 Service Manual

Classic high voltage controller (hv3 - handguns)
Hide thumbs Also See for 9060:
Table of Contents

Advertisement

Reset Button
The reset button is used in the normal operating mode
to clear fault or overload conditions when the trigger
signal is OFF. This will NOT prevent any other active
fault conditions from triggering a new fault.
† There is a 5 second fault reset delay timer that
inhibits the triggering of high voltage immediately
after a fault reset.
HV Control Button
This button, shown in the center of Figure 3, is not
functional for handgun units.
.

CONNECTION INTERFACE

The 9060 Controller connection interface shown in
Figure 4, provides all of the required connections for
setting up a local controlled painting system. This
connection interface consists of one (1) high voltage
cable connector, one (1) standard I/O connector, one (1)
interlock I/O connector, one (1) ground lug connection,
one (1) air flow switch connection, two (2) fuses, and
one (1) AC inlet receptacle.

CONNECTORS

High Voltage Cable Connector
The high voltage cable connector is the largest con-
nector and is located on the far right of the connection
interface.
The connector will come covered with a
factory installed red protective cap. This connector
is designed for use with standard high voltage cables
such as 79518 and 79519. The specific cable required
depends on the applicator being used. Please refer to
the applicator manual for the cable required.
Standard I/O Connector
The standard I/O connector is located just left of the high
voltage cable connector. This connector is provided
as the entry point for a shielded multi-conductor cable
used for remote I/O signals and includes the required
cable grommet hardware to keep the cable in place
with minimal strain. This connector is NOT used for
handgun units.
CP-17-02
9060 Classic High Voltage Controller -
NOTE
Figure 4: 9060 Connection Interface
Interlock I/O Connector
The interlock I/O connector is located just above the
AC inlet receptacle. This connector is provided as the
entry point for interlock signal wiring for the booth fan,
conveyor, and solvent supply. The connector includes
the required cable grommet hardware to keep wiring
in place with minimal strain. For more information on
the interlock connections, please see the "Installation"
section of the service manual.
Ground Lug Connection
The ground lug connection is located directly below the
fuses and has a ground logo sticker directly below it.
This lug is provided as an external ground connection
point used to ground the 9060 to an earth ground via
a ground cable. This ground lug connection can also
be used as the ground point for the high voltage cable
ground.
Air Flow Switch Connection
The air flow switch connection is installed to provide a
pneumatic trigger signal for handguns indicating that
the trigger has been actuated. This signal is used to
turn on the High Voltage output. Both threaded con-
nectors of the air flow switch will come covered with
red protected caps.
AC Inlet Receptacle
The AC inlet receptacle is a standard IEC C14 Appliance
Inlet connector with a maximum rating of 250 VAC. It
can handle both 110VAC and 240 VAC inputs at 50 or
60 Hz. The unit is shipped with the appropriate rated
AC cord for the particular installation.
INTRODUCTION