Note:Once the battery is disconnected, the loads are not protected from
power outages.
1.
Use an insulated philip screwdriver to remove the four screws located
at the base of the UPS.
2.
Remove the front panel and top cover.
3.
Use an insulated philip screwdriver to remove the two screws from the
battery holding plate. (for 1500L/1800L/2200L only)
4.
Disconnect the battery cable terminals before removing the battery from
the UPS.
Step1: Loosen the black cable from the negative (-) terminal.
Step2: Loosen the red cable from thepositive (+) terminal.
Refer to the steps below should the UPS fail to
function correctly
Step 1: Is the AC Mains switch in the "ON"
position?
Step 2:Is the UPS plugged into the AC power
supply?
Step 3: Is the power supply within specified unit
values?
Step 4: Has the fuse gone in the mains plug?
Step 5: Is the UPS overload?
Step 6: Is the battery flat or defective?
Description
Model
Capacity
Input
Voltage
Voltage Range
Output
Voltage Regulation
Transfer Time
Waveform
Battery
Type & Number
Charging time
Physical
Dimension (WxHxD, mm)
Net Weight (kg)
Packaging Dimension
(WxHxD,mm)
Gross Weight (kg)
Environment
Humidity
Noise level
Certification
Safety Standard
EMC/Surge Standard
Mark
5.
Note: Small sparks at the battery connectors are normal during connection.
6.
7.
8.
9.
STEP2
STEP1
GR600/GR800
TROUBLESHOOTING
Situation
Battery voltage is low.
No LEDs display on the front
Battery is defective.
panel.
The UPS is not turned on.
Alarm beeps continuously
The UPS is overloaded.
when the Utility is normal.
The UPS is overloaded.
UPS does not provide
expected backup time.
Battery voltage is too low.
Battery is defective.
The Utility is normal but LED
Power cord is loose.
is flashing.
Ablerex GR600/GR800 SPECIFICATIONS
GR600
600VA/300W
800VA/400W
12V/7Ah x 1
12V/9Ah x 1
100 x 140 x 292
4.5
137 x 226 x 321
5.5
Connect the battery cables to the terminals of thenew battery.
Step1: Insert the black cable to the negative (-) terminal.
Step2: Insert the red cable to thepositive (+) terminal.
Slide the battery into the UPS.
Use an insulated philip screwdriver to fasten the two screws on the battery holding plate. (for 1500L/1800L/2200L
only)
Close the front panel and fasten the four screws located at the base of the UPS.
Dispose off the old battery properly at an appropriate recycling facility.
STEP1
STEP2
Problem / Possible Causes
Charge the UPS at least 6 hours.
Replace the battery with the same capacity.
Press the power switch again to turn on the UPS.
Remove some loads/equipment first. The connected equipment exceeds the
UPS specified 'capacity/load".
Remove some loads/equipment first. The connected equipment exceeds the
UPS specified 'capacity/load".
Charge the UPS at least6 hours.
Replace the battery with the same capacity.
Reconnect the power cord properly.
Ablerex GR1200/GR1800/GR2000 SPECIFICATIONS
GR800
GR1200
1200VA/600W
220/230/240VAC
160~290Vac
+/- 10%
Typical 2-6ms, 10 ms max.
Simulated Sine Wave
12V/7Ah x 2
4-6 hours recover to 90% capacity
5
8
6
9
0-90 % RH @ 0-40 C (non-condensing)
Less than 40 dB
EN62040-2
EN61000-3-2, EN61000-3-3
CE, RoHS, TISI
GR1200/GR1800/GR2000
Solution
GR1800
GR2000
1800VA/900W
2000VA/1200W
12V/7Ah x 2
12V/9Ah x 2
148 x 198 x 315
11
229 x 302 x 411
12
12
13