Appendix 3.5 R301 Cable Manufacturing Drawing

Application:
Assembly drawing
Remote I/O unit
(FCU6-DX561) side
DI-L/-R
DO-L
Manufacturing precautions
(1) The parts used shall be Mitsubishi recommended parts. Equivalent parts may be used providing
they are compatible with the specifications.
(2) Attach the nameplate (with protective cover stamped with the cable name) in the position designated
in the assembly drawing.
(3) The cable is the same for DI and DO. However, stamp DI or DO on the connector to prevent
incorrect insertion.
Downloaded from
ManualsNet.com
APPENDIX 3 CABLE MANUFACTURING DRAWING
Appendix 3.5 R301 Cable Manufacturing Drawing
DIO – Machine electric cabinet
1
search engine
No.
Connector
1
7940-6500SC
Strain relief
2
3448-7940
Wire material
3
B40-S
First wire is colored
1
2
3
R301
Note (2)
I-29
List of parts used
Part name/model
Maker
Sumitomo 3M
Sumitomo 3M
Note (1)
Max. cable length: 20m
Machine electric cabinet side
Qty.
2
1
(1)