Command Manual – System Maintenance and Debugging
H3C S3100-52P Ethernet Switch
Description
Use the schedule reboot delay command to enable the delay reboot function on the
switch, and set the reboot delay time.
Use the undo schedule reboot command to disable the delay reboot function.
By default, the delay reboot function is disabled on the switch.
Note that:
The switch timer is precise to one minute. When the reboot time reaches, the
switch will reboot in one minute at most.
You can set the reboot delay in two formats: the hour:minute format and the
absolute minute format, and both must be less than or equal to 30 × 24 × 60 (that
is, 30 days).
After you execute the command, the system will prompt you to confirm. Enter "Y"
or "y" for your setting to take effect. Your setting will overwrite the previous one (if
there is a setting already exists).
If you adjust the system time by the clock command after executing the schedule
reboot delay command, the configured schedule reboot delay command will be
invalid and the scheduled reboot will not happen.
Related commands: reboot, schedule reboot at, undo schedule reboot, display
schedule reboot.
Examples
# Suppose the current time is 05:02, schedule a reboot so that the switch reboots after
70 minutes.
<Sysname> schedule reboot delay 70
Reboot system at 06:12 2000/04/02(in 1 hours and 10 minutes)
confirm?[Y/N]:y
<Sysname>

3.1.22 schedule reboot regularity

Syntax
schedule reboot regularity at hh:mm period
undo schedule reboot regularity
View
System view
Parameters
hh:mm: Reboot time of the switch, in the hour:minute format, where hh ranges from 0 to
24, and mm ranges from 0 to 59.
Chapter 3 Device Management Commands
3-21