Error
Error description
Code
E225
Connecting the main con-
trol board...
E226
Current file is invalid
E227
The file transfer failed
E228
Data outside the range
E229
The modified Angle is too
large
E230
Loading graph data...
E231
Foot follow error
E232
No U disk!
E233
File error!
E234
Graph or head offset out of
bounds!
E235
This is not a working file!
E236
TF RAM error
E237
Please set the admin pass-
word first
E238
Editing is not supported
E239
Please contact the manu-
facturer
Fault Cause
1. The screen cable interface is
loose or damaged
2. Screen or motherboard hardware
failure
1. Upgrade without selecting the
upgrade file
2. The read file is damaged or of
the wrong type
3. U disk is incompatible or dam-
aged
1. The screen cable interface is
loose or disconnected
2. The screen or motherboard pro-
gram is too old
3. Screen or motherboard hardware
failure
4. The screen line is tied with a
strong interference source
The current graphic file data ex-
ceeds the maximum format limit
Single modification of graph angle
value is too large
Processing necessary graphics data
1. The presser foot motor is stuck
when it rotates.
2. Parameter setting error
1. U disk is not inserted or damaged
2. The screen U disk interface is
damaged
An error occurred while reading or
writing from the USB flash drive
1. The file size is too large to ex-
ceed the processable range
2. The file is small but offset from
the processable range
3. Head offset is out of bounds
4. The parameters are set incor-
rectly, such as the size of the
pressure plate
File content or format error
Bad motherboard
No administrative password is set
No editing instructions or files
Contact the manufacturer
– 56 –
Solution
1. Check the screen cable for bad con-
tact or damage
2. Replace the screen or motherboard
1. Insert U disk and select upgrade file
2. Replace the correct documents
3. Replace U disk
1. Check the screen line
2. Upgrade the latest screen or mother-
board program
3. Test whether you can upgrade the
motherboard program; test whether
the communication is normal in the
"Test Transmission" interface, and
replace the hardware if it is abnormal
4. Separate screen wires from strong in-
terference wires such as motor power
wires
Check if the graphic data is abnormal
Decrease the modified angle value
Wait for a while before proceeding
1. Check if the presser foot motor is nor-
mal
2. Reset parameters
1. Re insert U disk or replace U disk
2. Insert other U disk interface or
change screen
1. Replace graphics files
2. Re insert U disk or replace U disk
1. Replace graphics with smaller height
and width
2. Reset the reference point position
3.Reset the head offset value of head 2
or head 3.
4. Set the platen size corresponding to
the machine
Replace Recognizable Graphics File
Replace the motherboard
Need to set an administrative password
first
No editing instructions or files
Contact equipment manufacturer