JUKI PS-800SB-2850 Instruction Manual page 56

Hide thumbs Also See for PS-800SB-2850:
Table of Contents

Advertisement

Error
Error description
Code
E134
Spindle overspeed
E135
Principal axis origin return
failed
E136
Phase loss of spindle bus
voltage
E137
Phase sequence error of
spindle motor
E138
UVW short to ground
E200
XY driver alarm
E201
X driver alarm
E202
Y driver alarm
E203
The main motor error
E204
The main motor direction
error
E205
Pressure box didn't put
down
E206
Failure of head board
Fault Cause
1. Wiring error
2. The acceleration is too high
3. The grid voltage is too low
4. Low spindle power
5. Short circuit of spindle to ground
Reverse phase sequence
1. The driver wiring is bad
2. The drive is damaged
1. The winding is normal but the
work occasionally reports that
the power board software and
hardware are too old
2. The spindle is stuck
3. The parameters are incorrect,
such as P665 to P668
4. The spindle encoder cable is
broken or has poor contact.
5. The spindle motor is broken
6. Power board or motherboard
hardware is bad
7. The motherboard and the power
board connected to the dress
rehearsal line poor cont act
1. The main motor direction param-
eter is set incorrectly.
2. Occasionally reported as a power
board failure
The current frame is in the raised
state
1. Bad head cable
2. The head plate is damaged
3. The motherboard is damaged
– 53 –
Solution
1. Check the line
2. Reduce acceleration
3. Check the input power
4. Select a spindle with a large power
level
5. Check whether the spindle is short
circuited to ground
Spare alarm
Spare alarm
Measure with a multimeter to restore the
correct phase sequence
E105
Refer to
Error Handling Method
1. Check the wiring
2. Replace the motherboard
Refer to
E200
Error Handling Method
E200
Refer to
Error Handling Method
1. See "Internal Drive Preview" - "Spin-
dle" - "Version Number" on the
screen. If it is lower than 2, you need
to update the program.
2. Manual rotation, check the machinery
3. Reset or redirect parameters
4. Check the wiring; manually turn
around to see if the screen QEP
changes one cycle, and see if the
"spindle 0 bit level" changes once. If
there is no change, it means that the
encoder wire is broken or the motor is
broken or the power board is broken.
5. Replace the spindle motor
6. Replace the power board or mother-
board
7. Check the connection cable
1. Change the main motor direction
parameter in the software or screen
2. Replace the power board
Click the "Frame" button to lower the
press frame
1. Check the headboard connection line
2. Replace the head board
3. Replace the motherboard

Advertisement